Description: Ejector Movement Failure RAP 11-320-120 The ejector is not at the home position. 11-322-120 The ejector fails to perform a cycle of operation. NOTE: A cycle of operation for the ejector is to move from the home position to the out position and back to the home position.
Remedy: NOTE: All 1K LCSS interlocks must be made to supply +24V to the motors. NOTE: In diagnostics, actuating any 1K LCSS sensor or switch can change the displayed state on the UI. Make sure that the correct sensor or switch is tested. NOTE: For clarity, the 1K LCSS is shown removed from the machine. Enter dC330, code 11-322, ejector out sensor, Q11-322. Actuate Q11-322. The display changes. Y↓N→Go to Flag 2. Check Q11-322. Refer to: • 11F-120 1K LCSS PWB Damage RAP. • GP 11 How to Check a Sensor. •. • P/J8, 1K LCSS PWB • 11C-120 1K LCSS Power Distribution RAP. Repair or install new components as necessary: • Ejector out sensor, Q11-322, PL 11.114 Item 3. • 1K LCSS PWB, PL 11.124 Item 1. Enter dC330, code 11-320, ejector home sensor, Q11-320. Actuate Q11-320. The display changes. Y↓N→Go to Flag 1. Check Q11-320. Refer to: • 11F-120 1K LCSS PWB Damage RAP. • GP 11 How to Check a Sensor. •. • P/J8, 1K LCSS PWB • 11C-120 1K LCSS Power Distribution RAP. Repair or install new components as necessary: • Ejector home sensor, Q11-320, PL 11.114 Item 3. • 1K LCSS PWB, PL 11.124 Item 1. Enter dC330, code 11-023 to check the operation of the ejector motor, MOT11-020. MOT11- 020 runs. Y↓N→Go to Flag 3. Check MOT11-020. Refer to: • 11F-120 1K LCSS PWB Damage RAP. • GP 10, How to Check a Motor. •. • P/J15, 1K LCSS PWB • 11C-120 1K LCSS Power Distribution RAP. Repair or Install new components as necessary: • Ejector assembly, PL 11.114 Item 1. • 1K LCSS PWB, PL 11.124 Item 1. The ejector cycles noisily, colliding with the end stops. Y↓N→Check the stapler to ensure the staples are correctly formed, refer to the 11-364-120 Stapling Failure RAP. Mis-formed staples can cause the set to hang in the stapler causing ejector movement failures. The staples are correctly formed. Y↓N→Clear the staple head of any mis-formed staples, then check the operation of the stapler. If necessary, install a new staple head unit, PL 11.116 Item 5. If the ejector is still not moving, install a new ejector assembly, PL 11.114 Item 1. Perform SCP 6 Final Actions. Go to Flag 4. +5V is available at P/J8 between pins 7 and 8. Y↓N→Go to the 11C-120 1K LCSS Power Distribution RAP. Connect a service meter at P/J8 between pins 8 and 9. Slowly rotate the ejector motor encoder. The voltage changes between +5V and 0V. Y↓N→Go to Flag 4. Check the wiring and connectors between the ejector motor encoder sensor and the 1K LCSS PWB. If necessary repair the wiring. If the wiring is good, install a new ejector motor encoder sensor, PL 11.114 Item 3. Perform the 11F-120 1K LCSS PWB Damage RAP, if necessary install a new 1K LCSS PWB, PL 11.124 Item 1.