Mã lỗi 10-101A, 10-102A, 10-103A — Xerox WorkCentre 5645

Code: 10-101A, 10-102A, 10-103A

Description: Lead Edge Late to Fuser Exit Switch RAP (32-55 ppm) 10-101 The lead edge of the paper failed to actuate the fuser exit switch within the correct time after the registration clutch was energized for a simplex sheet. 10-102 The lead edge of the paper failed to actuate the fuser exit switch within the correct time after the registration clutch was energized for a duplex sheet side 1. 10-103 The lead edge of the paper failed to actuate the fuser exit switch within the correct time after the registration clutch was energized for a duplex sheet side 2.
Remedy: • Make sure that the correct RAP is used. To identify the correct RAP to use, go to 10-101, 10-102, 10-103 Lead Edge Late to Fuser Exit Switch Entry RAP. • Check the condition of the paper in all trays. Refer to IQ1 and GP 20. • Check for obstructions in the registration transport. • Check for obstructions in the short paper path assembly. • Check that the short paper path assembly latches without excessive force, PL 10.25 Item 1. . In Replacement Step 5, check the latch mechanism. • Check the stripper fingers on the xerographic module. • Check for paper in the fuser module. • Check the fuser stripper fingers for contamination, (32-55 ppm) PL 10.8 Item 4. • If a 10-101 is caused by paper fed from the bypass tray, check for paper skew. • If a 10-103 is caused by a skewed sheet on side 2, check the inverter, PL 10.12 Item 1. Also check the duplex paper path (32-55 ppm) PL 8.22 Item 1. Install new components as necessary. • If 10-101 jams, check that all of the HT connectors are pushed fully home on the HVPS.
NOTE: The door interlock switch must be cheated when checking +24V components. Enter dC330 code 10-100 fuser exit switch, S10-100. Press Start. Manually actuate the switch with a piece of paper. The display changes. Y↓N→Go to Flag 1. Check S10-100. Refer to: • GP 13 How to Check a Switch. •. • P/J35, IOT PWB. • 01D +3.3V Distribution RAP. • 01B 0V Distribution RAP. Install new components as necessary: • Fuser exit switch, (32-55 ppm) PL 10.8 Item 11. • Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL 1.10 Item 2. Enter dC330 code 10-065 vacuum transport fan, MOT10-065.. Press Start, The fan runs. Y↓N→Go to Flag 2. Check MOT10-065. Refer to: • GP 10 How to Check a Motor. •. • P/J5, IOT PWB. • P/J17, LVPS. • Fuse, PL 1.10 Item 9, GP 7. • 01G +24V Distribution RAP. • 01B 0V Distribution RAP. Install new components as necessary: • Short paper path assembly, PL 10.25 Item 1. • Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL 1.10 Item 2. Enter dC330 code 04-010 main drive motor. Press Start. Add code 08-070 registration clutch, CL08-070. Press Start. NOTE: The clutch will switch off after 5 seconds. The jam clearance knob 4c, PL 8.15 Item 10, rotates. Y↓N→Go to Flag 3. Check CL08-070. Refer to: • GP 12 How to Check a Solenoid or Clutch. • P/J5, IOT PWB. • P/J17, LVPS. • Fuse, PL 1.10 Item 9, GP 7. • 01G +24V Distribution RAP. • 01B 0V Distribution RAP. Install new components as necessary: • Registration clutch, (32-55 ppm) PL 8.15 Item 7. • Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL 1.10 Item 2. Enter dC330 code 08-150 registration sensor, Q08-150. Press Start. Manually actuate the sensor. The display changes. Y↓N→Go to Flag 4. Check Q08-150. Refer to: • GP 11 How to Check a Sensor. •. • P/J5, IOT PWB. • 01D +3.3V Distribution RAP. • 01B 0V Distribution RAP. Install new components as necessary: • Registration sensor, (32-55 ppm) PL 8.15 Item 3. • Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL 1.10 Item 2. Check the following components, refer to GP 7: • Registration roll, PL 8.15 Item 9. • Roll assembly on the short paper path assembly, PL 10.25 Item 1. • Check the detack corotron and the connection to the HVPS. Refer to 09-060 HVPS Fault RAP • The drive gear on the fuser module, (32-55 ppm) PL 10.8 Item 1. • The fuser drive gear on the main drives module, (32-55 ppm) PL 4.17 Item 10. • Fuser web motor and the fuser web, 10A Fuser Web Motor RAP. • If the fault still occurs, check the drives plate on the registration clutch for damage and contamination. Refer to the replacement procedure.

← Xem tất cả mã lỗi Xerox WorkCentre 5645

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie