Mã lỗi 10A — Xerox WorkCentre 5645

Code: 10A

Description: Fuser Web Motor RAP Use this RAP when the fuser web motor is suspected of having failed. Indications of motor failure are contaminated stripper fingers and fuser roll. This fault may also cause paper jams in the inverter.
Remedy: NOTE: The door interlock switch must be cheated when checking +24V components. The web motor does not run continuously. It is pulsed on for multiples of 0.9 seconds duration. The pulsing of the motor is felt or heard during the print mode. Enter dC330 code 10-010 fuser web motor, MOT10-010. The movement is very slow (approximately 0.1 rev per minute). The motor runs. Y↓N→Go to Flag 1. Check MOT10-010. Refer to: •. • GP 10 How to Check a Motor. • P/J154, Main Drives PWB. • 01G +24V Distribution RAP. • 01B 0V Distribution RAP. Install new components as necessary: • Fuser web motor assembly, (32-55 ppm) PL 4.17 Item 1. • Fuser web motor assembly, (65-87 ppm) PL 4.12 Item 1. • Main drives module, (32-55 ppm) PL 4.15 Item 1. • Main drives module, (65-87 ppm) PL 4.10 Item 1. • Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL 1.10 Item 2. Check the following: • Drive coupling on the fuser web motor shaft, (65-87 ppm) PL 4.12 Item 1. • Drive coupling on the fuser web motor shaft, (32-55 ppm) PL 4.17 Item 1. • Drive coupling on the web assembly. The life expectancy of the fuser web is the same as the Fuser module. Install new Fuser module, (32-55 ppm) PL 10.8 Item 1, (65-87 ppm) PL 10.10 Item 1.

← Xem tất cả mã lỗi Xerox WorkCentre 5645

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie