Mã lỗi 09-365 — Xerox WorkCentre 5655

Code: 09-365

Description: Relative Humidity Sensor Failure RAP 09-365 Average humidity reading is out of limits. Also use this RAP if the relative humidity sensor is suspected of working incorrectly. A faulty relative humidity sensor can cause image quality problems.
Remedy: Enter dC330 code 09-365, relative humidity sensor, Q09-365. Press start. Observe the displayed state of Q09-365.. Open the bypass tray, gently blow on the relative humidity sensor PWB. Observe again the displayed state of Q09-365. The displayed state has changed. Y↓N→Go to Flag 1. Check for +5V at P/J7 pin 3 on the IOT PWB. +5V is present. Y↓N→Go to the 01E +5V Distribution RAP. Go to Flag 1. Check for +5V at P/J46 pin 1. +5V is present. Y↓N→Check the wiring between P/J7 on the IOT PWB and P/J46, GP 7. Repair wiring as necessary. Install a new relative humidity sensor / ambient temperature sensor, (32-38 ppm) PL 9.22 Item 4, (45-87 ppm) PL 9.20 Item 4. If the fault continues, perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL 1.10 Item 2. If possible, check the relative humidity of the external environment using a hygrometer. Compare with a reading from the sensor Q09-365. Refer to the NOTE above Table 1. If a hygrometer is not available refer to Table 1 for the approximate expected humidity value. Compare the expected values with Q09-365. If the value of Q09-365 is very different from the expected reading. Install a new relative humidity sensor / ambient temperature sensor, (32-38 ppm) PL 9.22 Item 4, (45-87 ppm) PL 9.20 Item 4. If the fault continues, perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL 1.10 Item 2. If the fault is intermittent, perform the steps that follow: • Check the wiring, GP 7. Repair if necessary. • Make sure that the P/Js are correctly and securely connected. NOTE: The actual value is not critical. If the reading from Q09-365 is approximately within the range indicated in column 4, Table 1, the sensor is good.
Relative humidity values External environment Average relative humidity Cold machine relative humidity Warm machine relative humidity
Wet 80% 80% 40% to 50% Ambient 50% 50% 15% to 30% Dry 10% 10% 1% to 7%

← Xem tất cả mã lỗi Xerox WorkCentre 5655

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie