Mã lỗi 09-370 — Xerox WorkCentre 5655

Code: 09-370

Description: Developer Temperature Sensor Failure RAP 09-370 The average developer temperature reading is out of limits.
Remedy: Enter dC330 code 09-370, developer temperature sensor Q09-370. Press start. Observe the displayed state of Q09-370. Remove the xerographic module. Disconnect P/J47. Cheat the front door interlock. Observe again the displayed state of Q09-370. The displayed state has changed. Y↓N→Go to Flag 1. Check for +5V at P/J7 pin 5 on the IOT PWB. +5V is present. Y↓N→Go to the 01E +5V Distribution RAP. Go to Flag 1. Check for +5V at P/J47 pin 3. +5V is present. Y↓N→NOTE: To gain access to the wiring, remove the main drive module, (32-55 ppm) PL 4.15 Item 1, (65-87 ppm) PL 4.10 Item 1 and the left hand cover, PL 8.10 Item 3. Check the wiring between P/J7 on the IOT PWB and P/J47. Repair the wiring as necessary. Install a new temperature sensor, (32-38 ppm) PL 9.22 Item 5, (45-87 ppm) PL 9.20 Item 5. If the fault persists. Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL 1.10 Item 2. Q09-370 is working correctly. Reconnect P/J47. If the fault is intermittent, perform the steps that follow: • Check the wiring, GP 7. Repair if necessary. • Make sure that the P/Js are correctly and securely connected.

← Xem tất cả mã lỗi Xerox WorkCentre 5655