Remedy: shows the component location. Switch off the machine, then switch on the machine, GP 14. The fault is still present. Y↓N→Perform SCP 6 Final Actions. Perform the following: • Remove the DADH. • Remove the scanner top cover. • Reinstall the DADH. Go to Flag 1 and check the voltages at P/J135 on the power distribution PWB. As necessary, refer to: • 01D +3.3V Distribution RAP. • 01F +12V Distribution RAP. • 01G +24V Distribution RAP. • 01B 0V Distribution RAP. Check the wiring between P/J135 on the power distribution PWB in the image processing module and P/J455 and P/J450 on the scanner PWB. Repair as necessary or install a new power distribution PWB/scanner PWB harness, PL 14.16 Item 7. Perform dC640 Video Path Diagnostics. The machine passes the diagnostic check. Y↓N→Check that all scanner harness connectors are correctly seated and that all wiring is in a good condition. Install new parts as necessary. Inspect the calibration strips on the front underside of the CVT glass and document glass. The calibration strips are undamaged. Y↓N→Install a new CVT glass, PL 14.10 Item 4 and/or a new document glass, PL 14.10 Item 5. Clean the white CVT strips, under the front edges of the document glass and the CVT glass, using a cleaning cloth dampened with film remover, PL 26.10 Item 4. Re-assemble the parts. If the fault persists, install new components as necessary: • Scan carriage assembly, PL 14.15 Item 1. • Scan carriage ribbon cable, PL 14.15 Item 4. • Scanner PWB, PL 14.16 Item 8. • Scanner, PL 14.10 Item 1. Exposure Lamp Check CAUTION When measuring voltages at P/J452 on the scanner PWB, take special care not to short any two pins together. Remove the document glass, go to Flag 2 and check the +24V at P/J452 on the scanner PWB. Measure between pins 2 and 4. If +24V cannot be measured, check that there is no short circuit between P/J452, pins 2 and 4. As necessary install new components: • Scanner PWB, PL 14.16 Item 8. • Exposure lamp ribbon harness, PL 14.15 Item 5. • Exposure lamp inverter, PL 14.15 Item 3. Measure the lamp enable signal between P/J452, pin 3 on the scanner PWB and the chassis, and enter the dC330 output code 14-005. Pin 3 is the centre contact on the body of the PJ. The signal should change from +24V to 0V. If the signal does not change, install a new scanner PWB, PL 14.16 Item 8. WARNING Do not install a fuse of a different type or rating. Installing the wrong type or rating of fuse can cause overheating and a risk of fire. Check the fuse, PL 14.15 Item 6 in the exposure lamp inverter. If necessary, install new components: • Fuse, PL 14.15 Item 6. • Exposure lamp, PL 14.15 Item 2. • Exposure lamp inverter, PL 14.15 Item 3. • Scan carriage assembly, PL 14.15 Item 1.