Description: Stapling Failure RAP 11-364-110 Staples in the stapling head are not primed.
Remedy: NOTE: In diagnostics, actuating any 2K LCSS sensor or switch can change the displayed state on the UI. Make sure that the correct sensor or switch is tested.. Enter dC330, code 11-361, actuate the SH 1 paper sensor, Q11-361. The display changes. Y↓N→Go to Flag 1 and check Q11-361. Refer to: • 11G-110 2K LCSS PWB Damage RAP. • GP 11, How to Check a Sensor. • P/J308, 2K LCSS PWB. • 11D-110 2K LCSS Power Distribution RAP. Repair or install new components as necessary: • SH 1 paper sensor, PL 11.20 Item 4. • 2K LCSS PWB, PL 11.26 Item 1. NOTE: If the SH1 priming sensor does not see staples in the primed position, the staple head cycles a number of times to prime the staple head. This occurs when the 2K LCSS interlocks are made. Follow the customer instruction label inside the 2K LCSS front door to remove the staple cartridge, slide out the top sheet of staples from the cartridge, to expose a fresh sheet of staples on the top of the stack. Ensure the forming plate is fully closed. Install the staple cartridge and close the door. The stapler will now cycle a few times to feed and prime the new sheet of staples. Open the door and remove the staple cartridge. Examine the sheet of staples that have been fed to the staple forming part of the stapler, by opening the forming plate. The first two staples have been partially formed. Y↓N→Install a new staple cartridge, PL 26.10 Item 11and repeat the check. If the first two staples are not partially formed, install a new staple head unit, PL 11.20 Item 5. Perform SCP 6 Final Actions Install a new staple head unit, PL 11.20 Item 5. Perform SCP 6 Final Actions.