Description: Power Off Failure RAP 03-374 The image processing PWB has detected that the LVPS is still on, 30 seconds after a power off request.
Remedy: Ensure the P/Js on the IOT PWB, PL 1.10 Item 2 and the image processing PWB, (32-55 ppm) PL 3.20 Item 3 or (65-87 ppm) PL 3.10 Item 3 are correctly and securely connected. The fault is still present. Y↓N→Perform SCP 6 Final Actions. Remove the left hand cover, PL 8.10 Item 3. Go to Flag 1. Measure the voltages at the on/off switch terminals. The voltages are +3.3V and 0V. Y↓N→Go to: • GP 13 How to check a switch. • P/J5. • 01B, 0V Distribution RAP. • 01J Power On and LVPS Control Signals RAP. • If necessary, install a new on/off switch, PL 1.10 Item 8. NOTE: The LVPS is software controlled. When the voltage on PJ26 is low, the LVPS should be on. When the voltage on PJ26 pin 7 is high, the LVPS should be off. Go to Flag 3. Measure the voltage at P/J26 pin 7 on the IOT PWB. Operate the on / off switch. Select power down then confirm from the UI. The voltage changes from low to high within 30 seconds. Y↓N→Install new components as required: • Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL 1.10 Item 2. • Image processing PWB, (32-55) PL 3.20 Item 3 or (65-87 ppm) PL 3.10 Item 3. Check the state of the LVPS by observing the power indication LEDs on the IOT PWB, (refer to the OF7 IOT PWB Diagnostics RAP). The LVPS has switched off. Y↓N→Install a LVPS and base module, PL 1.10 Item 3. Go to Flag 2. Measure the voltage at P/J1 pin 15 on the IOT PWB. Operate the on / off switch. A single low pulse is detected. Y↓N→Go to Flag 2. Check the wiring. Repair as necessary, GP 7. Install new components as necessary: • Image processing PWB, (32-55) PL 3.20 Item 3 or (65-87 ppm) PL 3.10 Item 3. • Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL 1.10 Item 2. Go to Flag 2. Set the meter to measure frequency. Check the pulses at P/J1 pin 13, on the IOT PWB. These are approximately 1Hz pulses. The pulses have stopped. Y↓N→Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL 1.10 Item 2. Perform the following: • Check that all associated wiring is in good condition, GP 7. • Reload the software, GP 4, Machine Software. • Image processing PWB, (32-55) PL 3.20 Item 3 or (65-87 ppm) PL 3.10 Item 3.

← Xem tất cả mã lỗi Xerox WorkCentre 5685

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie