Description: Tray 3 Elevator Lift Failure RAP 07-355 Tray 3 stack height sensor did not actuate within the correct time after the elevator motor turned on.
Remedy: Enter dC330 code 07-303 tray 3 home switch, S07-303. Press Start. Pull out the tray and push back in. The display changes. Y↓N→Go to Flag 1. Check S07-303. Refer to: • GP 13 How to Check a Switch. • P/J392, HCF control PWB. • 01E +5V Distribution RAP. • 01B 0V Distribution RAP Install new components as necessary: • Tray 3 home switch, PL 7.20 Item 4. • HCF control PWB, PL 7.20 Item 2. Enter dC330 code 07-383 tray 3 stack height sensor, Q07-383. Press Start. Pull out tray 3 and manually activate the stack height sensor on the paper feed assembly. The display changes Y↓N→Go to Flag 2. Check Q07-383. Refer to: • GP 11 How to Check a Sensor. • P/J392, HCF control PWB. • 01E +5V Distribution RAP. • 01B 0V Distribution RAP. Install new components as necessary: • Tray 3 stack height sensor, PL 8.30 Item 21. • HCF control PWB, PL 7.20 Item 2. Go to P/J396 pin 1 on the HCF control PWB, Flag 4. Manually activate the tray 3 stack limit switch (S07-393) on the paper feed assembly. The voltage changes. Y↓N→Go to Flag 3. Check S07-393. Refer to: • GP 13 How to Check a Switch. • P/J396, HCF control PWB. • 01G +24V Distribution RAP. • 01B 0V Distribution RAP. Install new components as necessary: • Tray 3 paper feeder, PL 8.30 Item 2. • HCF control PWB, PL 7.20 Item 2. CAUTION To prevent damage to the elevator and paper feed mechanism, the paper tray must be pulled out before MOT07-030 is run in diagnostics. Enter dC330 code 07-030 tray 3 elevator motor, MOT07-030. Pull out tray 3. Press Start. The motor runs Y↓N→Go to Flag 4. Check MOT07-030. Refer to: • GP 10 How to Check a Motor. • P/J395, HCF control PWB. • 01G +24V Distribution RAP. • 01B 0V Distribution RAP Install new components as necessary: • Tray 3 elevator motor, PL 7.20 Item 1. • HCF control PWB, PL 7.20 Item 2. Perform the following: • Check elevator cables, PL 7.15 Item 4, PL 7.15 Item 6, PL 7.15 Item 7. • Check elevator motor drive coupling, PL 7.20 Item 1. • Check tray elevator drive gears and drive coupling, PL 7.15. • Check the tray 3 empty sensor actuator, PL 8.30 Item 1. If the fault still occurs then go to 07E Tray 3 or Tray 4 Out of Paper RAP.