Description: Transfer / Detack Cleaning Failure RAP 09-345 The transfer / detack cleaning routine has failed to complete. The home sensor is not detected. 09-346 A transfer / detack cleaning warning detected. Home sensor detected, but may not be cleaning the full length of the wires
Remedy: NOTE: The front door interlock must be cheated when checking +24V components. Enter dC330 code 09-074 transfer / detack stall sensor. Press Start. Enter dC330 code 09-075 transfer / detack cleaner motor. Press Start. When the motor reaches the end of its travel, the stall sensor will go high / low. The motor runs and the stall sensor goes high / low. Y↓N→Go to Flag 2. Check MOT09-043. Refer to: • GP 10 How to Check a motor. • P/J65, IOT PWB. • 01G +24V Distribution RAP. • 01B 0V Distribution RAP. Install new components as necessary: • Transfer / detack motor (45-87 ppm), part of PL 10.25 Item 1. • Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL 1.10 Item 2. Remove the transfer / detack corotron. Enter dC330 code 09-073 transfer / detack cleaner home sensor. Press Start. Manually actuate the sensor The display changes. Y↓N→Go to Flag 1. Check Q09-070. Refer to: • GP 11 How to Check a Sensor. • P/J65, IOT PWB. • 01D +3.3V Distribution RAP. • 01B 0V Distribution RAP. Install new components as necessary: • Transfer / detack cleaner home sensor, (45-87 ppm), part of PL 10.25 Item 1 • Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL 1.10 Item 2. The fault can be intermittent, perform the following: • Check the wiring, GP 7. Repair if necessary. • Check for binding of the transfer / detack cleaner as it moves up and down the corotron shield. part of PL 10.25 Item 1. • Ensure that P/J65 on the IOT PWB is connected correctly. • Check for toner contamination on the front end of the short paper path. With the corotron removed, clean the contaminated area. Remove and clean the transfer / detack cleaner home sensor.