Mã lỗi 03-412 — Xerox WorkCentre 5687F

Code: 03-412

Description: Foreign Device PWB Fault RAP 03-412 A foreign interface device was not detected at power on.
Remedy: Use a foreign interface test tool (NASG/XCL only), PL 26.10 Item 22 to check the operation of the foreign interface device. If a foreign interface test tool is not available, perform the procedure that follows: Check the +3.3V LED on the foreign interface PWB. The LED is lit. Y↓N→Go to: • 01D +3.3V Distribution RAP. • 01B 0V Distribution RAP. Go to Flag 1. Check the harness. The harness is good. Y↓N→Perform the following as necessary: • Repair the harness. Refer to GP 7. • Install a new foreign interface harness, (32-55 ppm) PL 3.15 Item 5 or (65-87 ppm) PL 3.11 Item 4. NOTE: Do not attempt to repair the harness from PJ124 to the foreign device. While the foreign device is connected, go to Flag 2. Check the voltage at PJ124 pin 2. 0V is measured. Y↓N→Disconnect the foreign device. Install a temporary shorting link between pins 2 and 3 on P/J124. Check the voltage at PJ124 pin 2. 0V is measured. Y↓N→Install a new foreign interface PWB, (32-55 ppm) PL 3.15 Item 4 or (65-87 ppm) PL 3.11 Item 3. The foreign device is faulty. Disconnect the foreign device. Install a temporary shorting link between pins 1 and 3 on P/ J124. Check the display. Ensure the machine is now enabled to scan or print. The machine is enabled. Y↓N→Install new components as necessary: • Install a new foreign interface PWB, (32-55 ppm) PL 3.15 Item 4 or (65-87 ppm) PL 3.11 Item 3. • Image processing PWB, (32-55 ppm) PL 3.20 Item 3 or (65-87 ppm) PL 3.10 Item 3. The enable circuits are working correctly. Currently, signals used for billing, e.g. machine function, premium tray, etc. cannot be adequately measured with a standard meter. For a full description of the foreign interface connections at PJ124, refer to Foreign Interface Signal Descriptions. Foreign Interface Signal Descriptions NOTE: If a foreign interface vend adaptor, (32-55 ppm) PL 3.15 Item 8 or (65-87 ppm) PL 3.11 Item 8 is installed, the pin configuration at the output of the vend adaptor will differ from those described in Table 1 and shown. Refer to your technical specialist. Use Table 1 for a full description of the foreign interface connections at J124
Table 1 Foreign Interface Signal Descriptions Pin Signal Notes
1 Machine Enable Low when the foreign interface device is in credit. 2 Device Detected Low when the foreign interface device is detected. 3 0V OV to the device to supply pins 1 and 2. 4 Machine Function 0 Depends on the current machine function, refer to Table 2. 5 Machine Function 1 Depends on the current machine function, refer to Table 2. 6 Premium Tray Pulsed signal when fed paper is longer than 380mm or shorter than 200mm. Refer to Training & Info CD2. 7 Premium Selected Pulsed signal when Reduction/Enlarge or Multiple Image selected. This is set using the Tools menu. Refer to Training & Info CD2. 8 Copy Count Pulsed signal for each fed sheet. Not generated during job recovery. 9 Not used - 10 Copy Exit Pulsed signal for 100 - 140mS when sheet exits the fuser 11 0V Supply from the machine to the foreign interface device. 12 Not Ready Low when machine is not ready, e.g. warming up or fault. 13 Not used - 14 Not used - 15 Not used -
Table 2 Machine function coding
Job Machine Function 0 Machine Function 1 Notes
Copy 1 1 Copy jobs Print 0 1 Print jobs and FAX printing (FAX in) FAX 1 0 Not enabled Scan 0 0 Not enabled

← Xem tất cả mã lỗi Xerox WorkCentre 5687F

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie