Mã lỗi 09-060 — Xerox WorkCentre 5687F

Code: 09-060

Description: HVPS Fault RAP 09-060 The HVPS fault sensor has detected a high voltage fault. The HVPS fault will occur when: • The 24 volt supply is momentarily overloaded. • The charge grid or developer bias or transfer values drop. • A increase in DT (AC) output current. The HVPS fault will deactivate within 100 milliseconds after the removal of the fault.
Remedy: NOTE: The following are the only values that can be measured from the HVPS. • Charge scorotron grid, -425V +/- 21V • The two terminals identified as G are the same output. • Registration chute bias, -490V +/- 25V • The two terminals identified as CB are the same output. • Developer bias, -370V +20V / -50V NOTE: The charge, transfer and detack corotron have 47k Ohms arc suppression resistors within their harnesses. Check that the F1 surface mounted fuse on the IOT PWB is good. Refer to OF7 IOT PWB Diagnostics RAP, for the location of the F1 surface mounted fuse. The surface mounted fuse is good.
Y↓N→Perform the procedures that follow: • 01G +24V Distribution RAP and refer to the 01G Fused Distribution Check. • 01H Short Circuit and Overload RAP. Enter dC330. Select component code 09-060 HVPS fault and press save. Press start. A high signal indicates a fault or the front door interlock open. Add Component code 09-061 charge scorotron. Press start. Time out after 3 seconds. The display for code 09-060 is Low. Y↓N→Go to the Flag 1. Check the charge scorotron harness for open circuit or short circuit to ground, GP 7. The scorotron harness and connectors are good. Y↓N→Install a new charge scorotron harness, (32-55 ppm) PL 4.17 Item 18, (65-87 ppm) PL 4.12 Item 20. Install a new xerographic module, (32-38 ppm) PL 9.22 Item 2, (45-87 ppm) PL 9.20 Item 2. If the fault continues, install a new HVPS, PL 1.10 Item 5. Add component code 09-062 charge grid. Press start. Time out after 3 seconds. The display for code 09-060 is Low. Y↓N→Go to the Flag 1. Check the charge grid harness for open circuit or short circuit to ground, GP 7. The grid harness and connectors are good. Y↓N→Install a new charge grid harness, (32-55 ppm) PL 4.17 Item 19, (65-87 ppm) PL 4.12 Item 21. Install a new xerographic module, (32-38 ppm) PL 9.22 Item 2, (45-87 ppm) PL 9.20 Item 2. If the fault continues, install a new HVPS, PL 1.10 Item 5. Add component code 09-063 transfer corotron. Press start. Time out after 3 seconds. The display for code 09-060 is Low. Y↓N→Go to the Flag 2. Check the transfer corotron harness for short circuit to ground, GP 7. The transfer corotron harness and connectors are good. Y↓N→Install a new transfer / detack harness, (32-38 ppm) PL 9.22 Item 9, (45-87 ppm) PL 9.20 Item 9. Install a new transfer / detack corotron, (32-38 ppm) PL 9.22 Item 8, (45-87 ppm) PL 9.20 Item 8. If the fault continues, install a new HVPS PL 1.10 Item 5. Add component code 09-064 detack corotron. Press start. Time out after 3 seconds. The display for code 09-060 is low. Y↓N→Go to Flag 2. Check the detack corotron harness for short circuit to ground, GP 7. The detack corotron harness and connectors are good. Y↓N→Install a new transfer / detack harness, (32-38 ppm), PL 9.22 Item 9, (45-87), PL 9.20 Item 9. On the 32-38 ppm machine, install a new transfer / detack corotron, PL 9.22 Item 8. On the 45-87 ppm machine, install a new short paper path assembly, PL 9.20 Item 3. If the fault continues, install a new HVPS PL 1.10 Item 5. Add component code 09-065 registration chute bias. Press start. Time out after 90 seconds. The display for code 09-060 is low. Y↓N→Install a new HVPS PL 1.10 Item 5. Add component code 09-066 developer bias. Press start. Time out after 3 seconds. The display for code 09-060 is low. Y↓N→Go to Flag 3. Check the developer bias harness for short circuit to ground, GP 7. The developer harness and connectors are good. Y↓N→Install a new developer bias harness, (32-55 ppm) PL 9.17 Item 6, (65-87 ppm) PL 9.15 Item 6. Install a new HVPS PL 1.10 Item 5. Complete SCP 6 Final Actions.

← Xem tất cả mã lỗi Xerox WorkCentre 5687F

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie