Description: Ejector Movement Failure RAP 11-320-110 The ejector is not at the home position. 11-322-110 The ejector fails to perform a cycle of operation. NOTE: A cycle of operation for the ejector is to cycle from the home position to the out position and back to the home position.
Remedy: NOTE: All 2K LCSS interlocks must be made to supply +24V to the motors. NOTE: In diagnostics, actuating any 2K LCSS sensor or switch can change the displayed state on the UI. Make sure that the correct sensor or switch is tested. Enter dC330, code 11-322, actuate the ejector out sensor, Q11-322. The display changes. Y↓N→Go to Flag 2. Check Q11-322. Refer to: • 11G-110 2K LCSS PWB Damage RAP. • GP 11 How to Check a Sensor. •. • P/J304, 2K LCSS PWB. • 11D-110 2K LCSS Power Distribution RAP. Repair or install new components as necessary: • Ejector out sensor, Q11-322, PL 11.18 Item 3. • 2K LCSS PWB, PL 11.26 Item 1. Enter dC330, code 11-320, actuate the ejector home sensor, Q11-320. The display changes. Y↓N→Go to Flag 1. Check Q11-320. Refer to: • 11G-110 2K LCSS PWB Damage RAP. • GP 11 How to Check a Sensor. •. • P/J304, 2K LCSS PWB. • 11D-110 2K LCSS Power Distribution RAP. Repair or install new components as necessary: • Ejector home sensor, Q11-320, PL 11.18 Item 3. • 2K LCSS PWB, PL 11.26 Item 1. Enter dC330, code 11-023 to check the movement of the ejector. The ejector motor runs. Y↓N→Go to Flag 3. Check the ejector motor, MOT11-020. Refer to: • 11G-110 2K LCSS PWB Damage RAP. • GP 10, How to Check a Motor. •. • P/J303, 2K LCSS PWB. • 11D-110 2K LCSS Power Distribution RAP. Repair or Install new components as necessary: • Ejector assembly, PL 11.18 Item 1. • 2K LCSS PWB, PL 11.26 Item 1. The ejector cycles noisily, colliding with the end stops. Y↓N→Check the stapler to ensure the staples are correctly formed. Mis-formed staples can cause the set to hang in the stapler causing ejector movement failures. The staples are correctly formed. Y↓N→Clear the staple head of any mis-formed staples, then check the operation of the stapler. If necessary, install a new staple head unit, PL 11.20 Item 5. If the ejector is still not moving, install a new ejector assembly, PL 11.18 Item 1. Perform SCP 6 Final Actions. Go to Flag 4. +5v is available at P/J304 between pins 7 and 8. Y↓N→Go to the 11D-110 2K LCSS Power Distribution RAP. Connect a service meter at P/J304 between pins 8 and 9. Slowly rotate the ejector motor encoder. The voltage changes between +5V and 0V. Y↓N→Go to Flag 4. Check the wiring and connectors between the ejector motor encoder sensor and the 2K LCSS PWB. If necessary repair the wiring. If the wiring is good, install a new ejector motor encoder sensor, PL 11.18 Item 3. Perform the 11G-110 2K LCSS PWB Damage RAP, if necessary install a new 2K LCSS PWB, PL 11.26 Item 1.