Mã lỗi 03-360, 03-408 ... 03-410, 03-418 — Xerox WorkCentre 5735

Code: 03-360, 03-408 ... 03-410, 03-418

Description: IOT to Output Device Error RAP 03-360 The IOT to output device communications have failed. 03-408 The IOT has failed to detect the OCT at power on. 03-410 The system failed to detect the output device at power on. 03-418 The system has detected that the output device software is not compatible with the image processing software.
Remedy: NOTE: No parts of the OCT are spared. Where necessary, install a new OCT, PL 12.10 Item 2. NOTE: and show the external connections to the output devices. 1. As necessary, ensure that the connectors that follow are correctly and securely connected: • OCT Only. P/J495 on the OCT PWB, P/J151 on the Power and Control Module and P/J11 on the IOT PWB. • 1K LCSS Only. P/J3 on the 1K LCSS PWB, P/J151 on the Power and Control Module and P/J11 on the IOT PWB. • 2K LCSS Only. P/J301 on the 2K LCSS PWB, P/J151 on the Power and Control Module and P/J11 on the IOT PWB. 2. Go to Flag 1 and Flag 2. Check the harnesses. Repair as necessary, GP 7. 3. Perform the OF7 IOT PWB Diagnostics RAP. 4. OCT Only. If the problem persists install a new OCT, PL 12.10 Item 2. 5. 1K LCSS Only. Perform the following: • Go to the 11C-120 1K LCSS Power Distribution RAP. Check the +5V and +24V supply from the power supply module to the 1K LCSS PWB. Ensure that the voltages are steady. • Ensure that there is a good ground continuity between the power supply module, PL 11.124 Item 2 and the 1K LCSS frame. • Install new components as necessary: – Power supply module, PL 11.124 Item 2. – 1K LCSS PWB, PL 11.124 Item 1. 6. 2K LCSS Only. Perform the following: • Remove fuse F1 from the 2K LCSS PWB. Check the fuse. If the fuse is good, reinstall the fuse. If fuse F1 is blown, install a new 2K LCSS PWB, PL 11.26 Item 1. • Go to the 11D-110 2K LCSS Power Distribution RAP. Check the +5V and +24V supply from the power supply module to the 2K LCSS PWB. Ensure that the voltages are steady. • Ensure that there is a good ground continuity between the power supply module, PL 11.26 Item 2 and the 2K LCSS frame. • Install new components as necessary: – Power supply module, PL 11.26 Item 2. – 2K LCSS PWB, PL 11.26 Item 1 7. HVF and HVF BM Only. Perform the following: • Go to the 11A-171 HVF Power Distribution RAP. Check the +5V and +24V supply from the power supply module to the HVF PWB. Ensure that the voltages are steady. • Ensure that there is a good ground continuity between the power supply module, PL 11.157 Item 1 and the HVF frame. • Install new components as necessary: – Communications cable, PL 11.157. – Power supply module, PL 11.157 Item 1. 8. If the correct output device is not detected, go to Flag 3. Check that the voltages on the device ID lines are correct according to the table. Install new components as necessary: • Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL 1.10 Item 2. • 1K LCSS PWB, PL 11.124 Item 1. • 2K LCSS PWB, PL 11.26 Item 1. • HVF PWB, PL 11.157 Item 2. • OCT, PL 12.10 Item 2.

← Xem tất cả mã lỗi Xerox WorkCentre 5735

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie