Description: HVF BM Creasing RAP 11-061-171 The crease blade has failed to clear the crease blade home sensor. 11-416-171 The crease blade has failed to return to the home position.
Remedy: Enter dC330 code 11-416. Actuate the BM crease blade home sensor, by rotating the crease blade knob, so that the actuator moves into and out of the home sensor. The display changes. Y↓N→Go to Flag 1. Check the BM crease blade home sensor, Q11-416. Refer to: • GP 11, How to Check a Sensor. • P/J552, BM PWB. • 11A-171 HVF Power Distribution RAP. Install new components as necessary: • BM PWB, PL 11.166 Item 10. • Crease blade home sensor, PL 11.165 Item 1. Enter dC330 code 11-418. Actuate the BM crease blade motor encoder sensor, by slowly rotating the crease blade knob. The display changes. Y↓N→Go to Flag 2. Check the BM crease blade motor encoder sensor, Q11-418. Refer to: • GP 11, How to Check a Sensor. • P/J552, BM PWB. • 11A-171 HVF Power Distribution RAP. Install new components as necessary: • BM PWB, PL 11.166 Item 10. • BM crease blade motor encoder sensor, PL 11.165 Item 1. Enter dC330, code 11-061 to run the BM crease blade motor, MOT 11-061. The motor runs. Y↓N→Go to Flag 3. Check the BM crease blade motor, MOT 11-061. Refer to: • GP 10 How to Check a Motor. • P/J557, BM PWB. • 11A-171 HVF Power Distribution RAP. Install new components as necessary: • BM crease blade motor, PL 11.165 Item 3. • BM PWB, PL 11.166 Item 10. The fault may be intermittent, check for damaged wiring or bad connectors. If necessary install new components: