Code: E194-4034
Description: Sensor calibration error. Sensor calibration failed.
Causes: Multi sensor, multi sensor base, carriage PCB, or main controller PCB
Remedy: 1. Retry calibration in the service mode. 2. Visual check Remove foreign substances from the multi sensor base if any. 3. Replace the multi sensor. 4. Cable continuity check If continuity of the cable between the multi sensor and the carriage PCB is abnormal, repalce the cable. 5. Replace the carriage PCB. 6. Cable continuity check If continuity of the cable between the carriage PCB and the main controller PCB is abnormal, replace the cable. 7. Replace the main controller PCB.