Description: ROS Laser Failure RAP 06-340. The IOT PWB has not detected the ROS laser reaching the operating speed.
Remedy: Go to Flag 3. Connect a service meter to P/J2 pin 7 and make a set of 5 copies. 0V is measured at P/J2 pin 7 on the IOT PWB during run. Y↓N→The xerographic module is fully home and the front door is fully closed or the front door interlock is cheated. Y↓N→Correct the condition. Go to Flag 1. Disconnect P/J18 from the LVPS. Check the following voltages on the LVPS: • +24V between pins 1 and 2. • +3.3V between pins 3 and 4. The voltages are good. Y↓N→Go to the relevant RAP: • 01B 0V Distribution RAP, refer to the 3.3V return and 24V return. • 01D +3.3V Distribution RAP. • 01G +24V Distribution RAP. Enter the dC330 output code 06-020. Go to Flag 2. The ROS motor gives a distinctive ascending frequency sound, of a short duration (5 to 6 seconds) during transition from standby to run. Y↓N→Go to the 06-020 ROS Motor Failure RAP. NOTE: The ROS must be removed from the machine, to disconnect P/J122 and P/J121. The ROS PWB where P/J122 and P/J121 are connected may not be marked with the correct PJ numbers. P/J122 can be identified as a four way power harness. P/J121 can be identified as a seven way signal harness. Check the wiring at Flag 1, Flag 2 and Flag 3. The wiring is good. Y↓N→Repair the wiring or install new harness, PL 6.10 Item 5. Install a new ROS, PL 6.10 Item 4. Go to Flag 4. Check P/J113 on the single board controller PWB is securely connected. If the fault is still present, remove the ROS. Go to Flag 4. Ensure that PJ122 on the ROS is securely connected. If the fault is still present, go to Flag 4 and check the continuity of the ROS data cable ( P/J113 to P/J122). The ROS data cable is good. Y↓N→Install a new ROS power distribution/communications harness, PL 6.10 Item 5. Install new parts in the following order: • ROS, PL 6.10 Item 4. • Single board controller PWB, PL 3.24 Item 3. • Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL 1.10 Item 2.