Mã lỗi 11J-120 — Xerox WorkCentre 5740

Code: 11J-120

Description: 1K LCSS Poor Stacking RAP Use this RAP to find the cause of poor stacking in the 1K LCSS.
Remedy: Check the following; • Look for sets that are not dropping back fully in bin 1 and therefore not operating the bin 1 level sensors: – Large paper sizes should not be stacked on top of small paper sizes. – Ensure that the paper stack in each paper tray has been fanned. – Turn over the paper stack in each paper tray. – Ensure that all paper or other copy stock being used is within the size and weight specifications. Refer to GP 20 Paper and Media Size Specifications. – Try using a fresh ream of paper. – Ensure that the edge guides of all paper trays are adjusted correctly for the paper size and that the trays are fully closed. – Check that bin 1 is seated correctly and the bin 1 alignment clip is in position, PL 11.100 Item 13. • Labels must not be fed to bin 1, but to bin 0 only. • It is recommended that transparencies are fed to bin 0 whenever possible. • Check that bin 1 is level front to back, if necessary perform ADJ 11.1-120 1K LCSS Bin 1 Level. • Check that the bin 1 upper level sensor, Q11-332 is working correctly. Refer to the 11-030- 120, 11-334-120, 11-335-120, 11-336-120 Bin 1 Movement Failure RAP. • Check the operation of the front and rear tampers. Refer to 11-005-120, 11-006-120, 11- 310-120, 11-311-120 Front Tamper Move Failure RAP and 11-007-120, 11-008-120, 11- 312-120, 11-313-120, 11-319-120 Rear Tamper Move Failure RAP. • Check that the output device is not near an air conditioning or ventilation output duct. Air flow across the output bins can cause poor stacking. • Check if Mod. TAG L-013 LCSS bin 1 kit is installed on the finisher. – Machine that regularly process large stacks of A4/8.5x11 inch LEF paper should have the LCSS bin 1 W/TAG L-013 kit installed, PL 11.100 Item 10. – Machines that regular process small stacks of A4/8.5x11 inch LEF, A3/11x17 inch and A4/8.5x11 inch SEF paper should have the standard W/OTAG L-013 bin 1 installed, PL 11.100 Item 10. • Check the output copies for curl, refer to IQ5.

← Xem tất cả mã lỗi Xerox WorkCentre 5740

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie