Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 03-412 — Xerox WorkCentre 5745

Code: 03-412

Description: Foreign Device PWB Fault RAP 03-412 The foreign interface device was not detected at power on.
Remedy: NOTE: Do not attach a foreign interface vend adaptor with this configuration of foreign interface PWB. Procedure Go to Flag 1. Check the harness. The harness is good. Y↓N→Perform the following as necessary: • Repair the harness. Refer to GP 7. • Install a new foreign interface harness, PL 3.22 Item 5. NOTE: Do not attempt to repair the harness from PJ124 to the foreign device. Check the +3.3V supply to P/J201 at pins 1, 5, 9, 16 and 22 on the single board controller PWB, The +3.3V supply is good. Y↓N→Go to: • 01D +3.3V Distribution RAP. • 01B 0V Distribution RAP. Disconnect the foreign device. Install a temporary shorting link between pins 2 and 3 on P/ J124. Check the voltage at PJ124 pin 2. 0V is measured. Y↓N→Install a new foreign interface PWB, PL 3.22 Item 4. If the fault remains, the foreign device is faulty. Disconnect the foreign device. Install a temporary shorting link between pins 1 and 3 on P/ J124. Check the display. Ensure the machine is now enabled to scan or print. The machine is enabled. Y↓N→Install new components as necessary: • Install a new foreign interface PWB, PL 3.22 Item 4. • Single board controller PWB, PL 3.24 Item 3. The enable circuits are working correctly. NOTE: Currently the signals used for billing, e.g. machine function, premium tray, etc. cannot be adequately measured with a standard meter.

← Xem tất cả mã lỗi Xerox WorkCentre 5745

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie