Code: 09-060
Description: HVPS Fault RAP 09-060 The HVPS fault sensor has detected a high voltage fault. The HVPS fault will occur when: • The (C) charge high voltage supply has a short or open circuit. • The (G) charge grid high voltage supply has a short or open circuit. • The (T) transfer high voltage supply has a short circuit. • The (DT) detack high voltage supply has a short circuit. • The (DB) developer bias high voltage supply has a short circuit. • The +24V supply to the HVPS has a short or open circuit. • The 24 volt supply is momentarily overloaded. The HVPS fault will deactivate within 100 milliseconds after the removal of the fault.
Remedy: If you were directed from IQ8 Defect RAP, continue below. If the following checks do not resolve the image quality problem, return to IQ3 Xerographic RAP. NOTE: The following are the only values that can be measured from the HVPS. • Charge scorotron grid, -425V +/- 21V. • The two terminals identified as G are the same output. • Registration chute bias, -490V +/- 25V. • The two terminals identified as CB are the same output. • Developer bias, -370V +20V / -50V. NOTE: The charge, transfer and detack corotron have 47k Ohms arc suppression resistors within their harnesses. Check that the F1 surface mounted fuse on the IOT PWB is good. Refer to OF7 IOT PWB Diagnostics RAP, for the location of the F1 surface mounted fuse. The surface mounted fuse is good. Y↓N→Perform the procedures that follow: • 01G +24V Distribution RAP and refer to the 01G Fused Distribution Check. • 01B 0V Distribution RAP. • 01H Short Circuit and Overload RAP. Enter dC330. Select component code 09-060 HVPS fault and press save. Press start. A high signal indicates a fault or the front door interlock open. Add Component code 09-061 charge scorotron. Press start. Time out after 3 seconds. The display for code 09-060 is Low. Y↓N→Go to the Flag 1. Check the charge scorotron harness for open circuit or short circuit to ground, GP 7. The scorotron harness and connectors are good. Y↓N→Install a new charge scorotron harness, (35-55 ppm) PL 4.17 Item 18, (65-90 ppm) PL 4.12 Item 20. Install a new xerographic module, (35 ppm) PL 9.22 Item 2, (40-90 ppm) PL 9.20 Item 2. If the fault continues, install a new HVPS, PL 1.10 Item 5. Add component code 09-062 charge grid. Press start. Time out after 3 seconds. The display for code 09-060 is Low. Y↓N→Go to the Flag 1. Check the charge grid harness for open circuit or short circuit to ground, GP 7. The grid harness and connectors are good. Y↓N→Install a new charge grid harness, (35-55 ppm) PL 4.17 Item 19, (65-90 ppm) PL 4.12 Item 21. Install a new xerographic module, (35 ppm) PL 9.22 Item 2, (40-90 ppm) PL 9.20 Item 2. If the fault continues, install a new HVPS, PL 1.10 Item 5. Add component code 09-063 transfer corotron. Press start. Time out after 3 seconds. The display for code 09-060 is Low. Y↓N→Go to the Flag 2. Check the transfer corotron harness for short circuit to ground, GP 7. The transfer corotron harness and connectors are good. Y↓N→Install a new transfer / detack harness, (35 ppm) PL 9.22 Item 9, (40-90 ppm) PL 9.20 Item 9. Install a new transfer / detack corotron, (35 ppm) PL 9.22 Item 8, (40-90 ppm) PL 9.20 Item 8. If the fault continues, install a new HVPS PL 1.10 Item 5. Add component code 09-064 detack corotron. Press start. Time out after 3 seconds. The display for code 09-060 is low. Y↓N→Go to Flag 2. Check the detack corotron harness for short circuit to ground, GP 7. The detack corotron harness and connectors are good. Y↓N→Install a new transfer / detack harness, (35 ppm), PL 9.22 Item 9, (40-90), PL 9.20 Item 9. On the 30 ppm machine, install a new transfer / detack corotron, PL 9.22 Item 8. On the 40-90 ppm machine, install a new transfer / detack corotron, PL 9.20 Item 8. If the fault continues, install a new HVPS PL 1.10 Item 5. Add component code 09-065 registration chute bias. Press start. Time out after 90 seconds. The display for code 09-060 is low. Y↓N→Install a new HVPS PL 1.10 Item 5. Add component code 09-066 developer bias. Press start. Time out after 3 seconds. The display for code 09-060 is low. Y↓N→Go to Flag 3. Check the developer bias harness for short circuit to ground, GP 7. The developer harness and connectors are good. Y↓N→Install a new developer bias harness, (35-55 ppm) PL 9.17 Item 6, (65-90 ppm) PL 9.15 Item 6. Install a new HVPS PL 1.10 Item 5. Complete SCP 6 Final Actions.