Mã lỗi 03-365 — Xerox WorkCentre 5755

Code: 03-365

Description: IOT Bus Failure RAP 03-365 The communications driver has failed. NOTE: This fault code can occur when the driver fails because of system electrical noise.
Remedy: NOTE: The IOT controller should clear an I2C bus fault indication after five seconds. 1. Ensure the P/Js on the IOT PWB, PL 1.10 Item 2 are correctly seated. 2. Check that there is continuity between the upper and lower registration guide. Ensure that the screw that secures the upper and lower registration guides is tight. 3. Check that there is continuity between the halo guide and the registration guide. Raise and lower the short paper path assembly, PL 10.15, several times to ensure that the continuity is consistent. If the continuity is inconsistent, perform the following: • Examine the registration and halo guide bias contact for deformation or damage, PL 8.15 Item 23. • Ensure the transfer / detack harness is routed correctly at the rear of the short paper path, refer to. 4. This fault may be caused by a ground fault, perform 01A Ground Distribution RAP. 5. Reload the software, GP 4 Machine Software. 6. Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL 1.10 Item 2.