Description: HVF Docking and Interlock RAP 11-300-171 The finisher was detected to be undocked in the run mode. 11-302-171 The top cover interlock was detected open during a run. 11-303-171 The finisher front door interlock was detected open during a run.
Remedy: Go to the appropriate RAP: • 11-300-171 Docking Interlock RAP • 11-302-171 Top Cover Interlock RAP • 11-303-171 Front Door Interlock RAP 11-300-171 Docking Interlock RAP Check the docking interlock switch, S11-300. • Check the switch actuator mounted on the machine is correctly installed and un-broken. • Enter dC330, code 11-300, actuate the switch and check the display. Refer to: – GP 13 How to Check a Switch. – P/J112, HVF Control PWB –, Flag 3. • Check the wiring, GP 7. • If necessary, install new components: – Docking interlock switch, PL 11.130 Item 16. 11-302-171 Top Cover Interlock RAP Check the top cover interlock switch, S11-302. • Check the switch actuator is not damaged. • Enter dC330, code 11-302 actuate the switch and check the display. Refer to: – GP 13 How to Check a Switch. – P/J112, HVF Control PWB. –, Flag 1. • Check the wiring, GP 7. • If necessary, install a new front door interlock switch, PL 11.145 Item 29. 11-303-171 Front Door Interlock RAP Check the front door interlock switch, S11-303. • Check the switch actuator on the inside of the front door is not damaged. • Enter dC330, code 11-303 actuate the switch and check the display. Refer to: – GP 13 How to Check a Switch. – P/J112, HVF Control PWB. –, Flag 2. • Check the wiring, GP 7. • If necessary, install a new front door interlock switch, PL 11.145 Item 29.