Mã lỗi 03-300, 03-306, 03-461, 03-482, 03-805, 03-870 — Xerox WorkCentre 5765

Code: 03-300, 03-306, 03-461, 03-482, 03-805, 03-870

Description: Single Board Controller PWB to IOT PWB Error RAP 03-300 The single board controller PWB to IOT communications have failed. 03-306 The IOT PWB has received an inappropriate print command from the single board controller PWB. 03-461 A speed mismatch has been detected between the single board controller PWB and the IOT PWB, in the NVM settings. 03-482 The single board controller PWB has failed to receive a +24V on signal from the IOT PWB. 03-805 The IOT PWB has received an un-recognized message from the single board controller PWB. 03-870 The IOT PWB cannot be recognized by the single board controller PWB.
Remedy: 1. Switch off the machine, GP 14. Ensure all the connectors on the single board controller PWB, PL 3.24 Item 3 and the IOT PWB, PL 1.10 Item 2 are correctly and securely seated. Switch on the machine, GP 14. 2. If the fault was detected during a software upgrade, go to Flag 1. Check P/J107 on the single board controller PWB. Re-load the software set, GP 4 Machine Software. 3. Perform OF7 IOT PWB Diagnostics RAP. 4. Go to Flag 2. Check the wiring, GP 7. If necessary, install a new single board controller PWB module / LVPS / IOT PWB harness, PL 3.24 Item 14. 5. 03-461 Only: Go to the OF7 IOT PWB Diagnostics RAP. Check CR 27 for an indication of NVM Test Failure. 6. Install a new IOT PWB, PL 1.10 Item 2. Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed. 7. Install a new single board controller PWB, PL 3.24 Item 3.

← Xem tất cả mã lỗi Xerox WorkCentre 5765

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie