Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 03-320 ... 03-324 — Xerox WorkCentre 5765

Code: 03-320 ... 03-324

Description: Single Board Controller PWB to DADH Error RAP 03-320 Communications between the single board controller PWB and the DADH have failed. 03-321 Communications between the single board controller PWB and the DADH are out of sequence. 03-322 The DADH has detected a read/write error. 03-323 The DADH has detected a software error. 03-324 The DADH has detected a boot check sum error.
Remedy: 1. Ensure all the connectors on the PWBs that follow are correctly and securely seated: • Single board controller PWB, PL 3.24 Item 3. • Scanner daughter PWB, PL 3.24 Item 20. • Power distribution PWB, PL 3.24 Item 5. • DADH PWB, PL 5.10 Item 5. Check also, the in-line connector in the communications/power cable, PL 5.10 Item 6. 2. Go to Flag 2. Check the voltages. Refer to: • 01B 0V Distribution RAP. • 01D +3.3V Distribution RAP. • 01G +24V Distribution RAP. 3. Go to Flag 1 and Flag 2. Check the wiring, GP 7. If necessary, install a new communication/ power cable, PL 5.10 Item 6. 4. If the fault was detected during a software upgrade, go to Flag 3. Check the connection. Reload the software, GP 4, Machine Software. 5. Install new components as necessary: • Single board controller PWB, PL 3.24 Item 3. • DADH PWB, PL 5.10 Item 5.

← Xem tất cả mã lỗi Xerox WorkCentre 5765