Code: 05-345, 05-346
Description: DADH Exit Sensor Failure RAP 05-345 The DADH exit sensor does not detect the lead edge of the document within the correct time in the forward mode. 05-346 The DADH exit sensor does not detect the trail edge of the document within the correct time in the forward mode.
Remedy: NOTE: On 35 ppm machines, the DADH exit sensor is actuated by a flag. On 40-90 ppm machines, the DADH exit sensor is a reflective type sensor. Enter dC330 code 05-345 to check the DADH exit sensor, Q05-345. Raise the DADH. Activate Q05-345. The display changes. Y↓N→Go to Flag 1. Check Q05-345. References: • GP 11 How to Check a Sensor. • P/J189, DADH PWB. • (35 ppm) 01D +3.3 Distribution RAP. • (35 ppm) 01B 0V Distribution RAP, refer to the 3.3V return. • (40-90 ppm) 01E +5V Distribution RAP. • (40-90 ppm) 01B 0V Distribution RAP, refer to the 5V return. Install new components as necessary: • DADH exit sensor, PL 5.30 Item 2. • DADH PWB, PL 5.10 Item 5. Close the DADH. Open the DADH top cover. Remove the DADH rear cover, PL 5.10 Item 1. Hold the top cover interlock switch closed. Enter dC330 code 05-030 to run the DADH CVT motor, MOT05-030. MOT05-030 runs. Y↓N→Go to the 05D DADH Motor Failure RAP. The CVT roll rotates. Y↓N→Perform the steps that follow: • Check the CVT motor drive belt, PL 5.25 Item 11. • Check the CVT motor tension spring. Check the CVT motor drive belt tension, ADJ 5.1. • Check the CVT roll pulley, refer to GP 7. If necessary, install a new DADH CVT roll, PL 5.25 Item 5. NOTE: The exit roll idlers remain lowered for 30 seconds. Enter dC330 code 05-050 to energize the DADH duplex solenoid, SOL05-050, to lower the exit roll idlers. The exit roll idlers lower. Y↓N→Perform the steps that follow: • Go to Flag 2. Check SOL050-050. References: – GP 12 How to Check a Solenoid or Clutch. – P/J181, DADH PWB and P/J205. – 01D +3.3V Distribution RAP. – 01B 0V Distribution RAP, refer to the 3.3V return. • Check the baffle assembly link arm, PL 5.30 Item 13. Make sure that the link arm is connected correctly to the DADH duplex solenoid, refer to. Install new components as necessary: • DADH duplex solenoid, PL 5.30 Item 4. • DADH PWB, PL 5.10 Item 5. • Baffle assembly, PL 5.30 Item 5. Enter dC330 code 05-020 to run the DADH feed motor, MOT05-020. MOT05-020 runs. Y↓N→Go to the 05D DADH Motor Failure RAP. The exit roll rotates. Y↓N→Perform the steps that follow: • Check the feed motor drive belt, PL 5.35 Item 5. • Check the feed motor tension spring. Check the feed motor drive belt tension, ADJ 5.1. • Check the exit roll and pulley, PL 5.35 Item 6 and PL 5.35 Item 15, refer to GP 7. If necessary, install a new DADH input tray assembly, PL 5.35 Item 1. The fault only occurs in duplex mode. Y↓N→Go to Final Actions. NOTE: During normal operation, the exit roll idlers remain raised (closed) in simplex mode. In duplex mode, the exit roll idlers remain raised unless the document is longer than 280mm (11 inches). The exit roll idlers raise and lower while feeding longer documents in duplex mode. Exit the diagnostics mode. Close the DADH top cover. Make two copies in duplex mode. Check that the second document is held in the feed rolls until the first document is fed into the output tray. The feed rolls held the second document. Y↓N→Go to the 05E DADH Feed Clutch Failure RAP. Go to Final Actions. Final Actions Perform the steps that follow: • For 05-345 and 05-346 faults: – Check that the pre-scan idlers are clean and rotate freely, refer to ADJ 5.4. – Check that the post-scan idlers are clean and rotate freely, refer to ADJ 5.4. – Check the CVT ramp assembly for damage and rough edges, (W/O TAG 150) PL 14.20 Item 13 or (W/TAG 150) PL 14.10 Item 13. – Check the duplex gate for damage and rough edges, PL 5.25 Item 12. – Check that Q05-345 is installed correctly. – Make sure that the DADH ground harness is connected correctly, PL 5.10 Item 11. – Make sure the feed motor drive belt and CVT motor drive belt are tensioned correctly, ADJ 5.1. Install new components as necessary: – Top access cover assembly, PL 5.20 Item 17. – Baffle assembly, PL 5.30 Item 5. • For 05-346 faults: – Make sure that the exit rolls are clean and rotate freely, refer to ADJ 5.4. – Make sure that the exit roll idlers are clean and rotate freely, refer to ADJ 5.4. – Make sure the tension springs on the exit roll shaft are in the correct position, refer to – Check the exit roll static eliminator and ground harness, PL 5.35 Item 7. – Check the restack arm for damage or rough edges, PL 5.35 Item 3. Install new components as necessary: – DADH exit roll, PL 5.35 Item 6. – DADH input tray assembly, PL 5.35 Item 1. If the fault continues, make sure that documents correctly exit the previous sensor in the document path. Refer to the 05-340 DADH Registration Sensor Failure RAP.