Description: Tray 4 Elevator Lift Failure RAP (W/O TAG 151)
Remedy: Enter dC330 code 07-304 tray 4 home switch, S07-304. Press Start. Pull out the tray and push back in. The display changes. Y↓N→Go to Flag 1. Check S07-304. Refer to: • GP 13 How to Check a Switch. • P/J392, HCF control PWB. • 01E +5V Distribution RAP. • 01B 0V Distribution RAP. Install new components as necessary: • Tray 4 home switch, PL 7.20 Item 4. • HCF control PWB, PL 7.20 Item 2. Enter dC330 code 07-384 tray 4 stack height Sensor, Q07-384. Press Start. Pull out tray 4 and manually actuate the stack height sensor on the paper feed assembly. The display changes. Y↓N→Go to Flag 2. Check Q07-384. Refer to: • GP 11 How to Check a Sensor. • P/J392, HCF control PWB. • 01E +5V Distribution RAP. • 01B 0V Distribution RAP. Install new components as necessary: • Tray 4 stack height sensor, PL 8.31 Item 13. • HCF control PWB, PL 7.20 Item 2. Go to P/J398 pin 6 on the HCF control PWB, Flag 4. Manually activate the tray 4 stack limit switch (S07-394) on the paper feed assembly. The voltage changes. Y↓N→Go to Flag 3. Check S07-394. Refer to: • GP 13 How to Check a Switch. • P/J398, HCF control PWB. • 01G +24V Distribution RAP. • 01B 0V Distribution RAP. Install new components as necessary: • Tray 4 paper feeder, PL 8.31 Item 4. • HCF control PWB, PL 7.20 Item 2. CAUTION To prevent damage to the elevator and paper feed mechanism, the paper tray must be pulled out before MOT07-040 is run in diagnostics. Enter dC330 code 07-040 tray 4 elevator motor, MOT07-040. Pull out tray 4. Press Start. The motor runs. Y↓N→Go to Flag 4. Check MOT07-040. Refer to: • GP 10 How to Check a Motor. • P/J397, HCF control PWB. • 01G +24V Distribution RAP. • 01B 0V Distribution RAP. Install new components as necessary: • Tray 4 elevator motor, PL 7.20 Item 1. • HCF control PWB, PL 7.20 Item 2. Perform the following: • Check elevator cables, PL 7.15 Item 4, PL 7.15 Item 5, PL 7.15 Item 7. • Check elevator motor drive coupling, PL 7.20 Item 1. • Check elevator drive gears and drive coupling, PL 7.15. • Check the tray 4 empty sensor actuator, PL 8.31 Item 1. If the fault still occurs then go to 07E Tray 3 or Tray 4 Out of Paper RAP.