Description: Fuser Over Temperature RAP 10-315 The difference between 2 consecutive thermistor readings exceeds a given value. 10-320 During standby or run mode, the thermistor reading is not within the target temperature range. 10-321 Over temperature during standby mode, the thermistor reading is not within the target temperature range 10-323 Over temperature during run mode, the thermistor reading is not within the target temperature range. 10-340 Fuser temperature sensor A reading monitors above its normal operating temperature. 10-350 The hardware comparator detects a fuser reading greater than 240 degrees centigrade or a short circuit thermistor. 10-360 Fuser temperature sensor B reading is greater than the normal operating temperature. 10-365 The fuser module is above the recommended operating temperature. 10-380 The fuser delta value between the temperature sensors A and B is to high.
Remedy: Switch off the machine, then switch on the machine, GP 14. The display shows Ready to Copy. Y↓N→Refer to. Go to Flag 1. The voltage at the temperature sensors A and B should be 2.9 volts when the sensors are cold. In standby mode the voltage should be 0.78 to 0.98 volts. Refer to: • P/J35, IOT PWB. • 01D +3.3 V Distribution RAP. • 01B 0V Distribution RAP Before new components are installed, restore the NVM values to default. Install new components as necessary: • Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL 1.10 Item 2. • LVPS and base module, PL 1.10 Item 3. • Fuser Module, (35-55 ppm) PL 10.8 Item 1, (65-90 ppm) PL 10.10 Item 1. Perform SCP 6 Final Actions.