Description: HVF 2nd to Top Exit Sensor RAP 11-140-171 The paper leading edge is late arriving at the 2nd to top exit sensor. 11-142-171 The paper trailing edge is late leaving the 2nd to top exit sensor.
Remedy: shows the location of the components. Enter dC330, code 11-140. Manually activate the 2nd to top exit sensor, Q11-140. The display changes. Y↓N→Go to Flag 1. Check the sensor, Q11-140. Refer to: • GP 11 How to Check a Sensor. • P/J101, HVF Control PWB • 11A-171 HVF Power Distribution RAP Install new components as necessary: • 2nd to top exit sensor, PL 11.156 Item 2. • HVF Control PWB, PL 11.157 Item 2 Enter dC330, code 11-002. Energize the exit diverter solenoid SOL 11-002. The solenoid energizes. Y↓N→Go to Flag 2. Check the solenoid, SOL 11-002. Refer to: • GP 12, How to Check a Solenoid or Clutch. • P/J102, HVF Control PWB • 11A-171 HVF Power Distribution RAP. Install new components as necessary: • Exit diverter solenoid, PL 11.150 Item 4. • HVF control PWB, PL 11.157 Item 2 Enter dC330, code 11-001 to run the exit feed motor 2, MOT 11-001. The motor runs. Y↓N→Go to Flag 3. Check the exit feed motor 2, MOT 11-001. Refer to: • GP 10 How to Check a Motor. • P/J102, HVF Control PWB • 11A-171 HVF Power Distribution RAP Install new components as necessary: • Exit feed motor 2, PL 11.150 Item 1. • HVF control PWB, PL 11.157 Item 2 Check the drive belt on the motor. The drive belt is good. Y↓N→Install a new drive belt, PL 11.150 Item 10. The fault may be intermittent, check for damaged wiring or bad connectors. If necessary install new components: • 2nd to top exit sensor, PL 11.156 Item 2. • Exit diverter solenoid, PL 11.150 Item 4. • Diverter gate, PL 11.153 Item 9. • Exit feed motor 2, PL 11.150 Item 1. • HVF control PWB, PL 11.157 Item 2. • Check if the HVF module has the W/TAG V-006 modifications installed. If the modifications have not been installed perform ADJ 11.13-171 HVF Performance Improvements W/ TAG V-006.