Mã lỗi 11D-110 — Xerox WorkCentre 5765

Code: 11D-110

Description: 2K LCSS Power Distribution RAP The 2K LCSS has an integral power supply providing +24V and +5V supplies to the 2K LCSS PWB. The AC power for the 2K LCSS power supply comes from the LVPS and base module of the machine.
Remedy: Close or cheat all the 2K LCSS interlocks. LED 2 on the 2K LCSS PWB is illuminated. Y↓N→+24V is available at Fuse (F1) on the 2K LCSS PWB. Y↓N→Go to Flag 2. Check for +24V between the following pins on P/J300: • Pin 1 and pin 2 • Pin 1 and pin 3 • Pin 1 and pin 6 • Pin 1 and pin 7 • Pin 5 and pin 2 • Pin 5 and pin 3 • Pin 5 and pin 6 • Pin 5 and pin 7 +24V is available between all the checked pins. Y↓N→Disconnect P/J300, check for +24V between the following pins on the end of the harness: • Pin 1 and pin 2 • Pin 1 and pin 3 • Pin 1 and pin 6 • Pin 1 and pin 7 • Pin 5 and pin 2 • Pin 5 and pin 3 • Pin 5 and pin 6 • Pin 5 and pin 7 +24V is available between all the checked pins on the end of the harness. Y N. Loosen the 4 screws and lift the power supply module away from the 2K LCSS frame. Go to Flag 1. ACL is available at CN1 between pins 1 and 3. Y↓N→Go to the 01C AC Power RAP and check the AC output voltages. Check the wiring between CN2 and P/J300. The wiring is good. Y↓N→Repair the wiring. Install a new power supply module, PL 11.26 Item 2. Check for a short circuit or an overload in the wiring or components connected to the +24V on the 2K LCSS PWB. Refer to GP 7. +24 V is available at PJ315 pin 5 on the 2K LCSS PWB. Y↓N→Go to the 11-300-110, 11-302-110, 11-303-110 Interlocks RAP. WARNING Do not install a fuse of a different type or rating. Installing the wrong type or rating of fuse can cause overheating and a risk of fire. Perform the following: • Switch off the machine, GP 14. • Go to Flag 3. Disconnect all the +24V harnesses to components. • Check each harness for short circuits and overheating, GP 7. • Repair or install new components as necessary. • Install a new fuse F1 on the 2K LCSS PWB, switch on the machine, GP 14. • Monitor the voltage at the left end of the fuse and re-connect the circuits one at a time. Energize the re-connected components using dC330 control codes. • If the voltage drops below +22V, switch off the machine, GP 14. Re-check the component and harness for overheating or short circuits. Repair or install new components as necessary. Perform the 11G-110 2K LCSS PWB Damage RAP, if necessary install a new 2K LCSS PWB, PL 11.26 Item 1. Go to Flag 2. +5V is available at P/J300 between pins 4 and 6, also between pins 7 and 8. Y↓N→Disconnect P/J300. +5V is available at P/J300 between pins 4 and 6, also between pins 7 and 8 on the end of the harness. Y↓N→Loosen the 4 screws and lift the power supply module away from the 2K LCSS frame. Go to Flag 1. ACL is available at CN1 between pins 1 and 3. Y↓N→Go to the 01C AC Power RAP and check the AC output voltages. Check the wiring between CN2 and P/J300. The wiring is good. Y↓N→Repair the wiring. Install a new power supply module, PL 11.26 Item 2. Check for a short circuit or overload in the wiring or components connected to +5V on the 2K LCSS PWB. Refer to GP 7. Perform the 11G-110 2K LCSS PWB Damage RAP, if necessary install a new 2K LCSS PWB, PL 11.26 Item 1.

← Xem tất cả mã lỗi Xerox WorkCentre 5765

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie