Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 14-703B ... 14-706B, 14-712B, 14-714B, 14-718B — Xerox WorkCentre 5765

Code: 14-703B ... 14-706B, 14-712B, 14-714B, 14-718B

Description: Failure To Calibrate RAP (W/TAG 150)
Remedy: shows the component location. Switch off the machine, then switch on the machine, GP 14. The fault is still present. Y↓N→Perform SCP 6 Final Actions. Perform the following: • Remove the DADH. • Remove the scanner top cover. • Reinstall the DADH. Go to Flag 1. Check the voltages at P/J135 on the power distribution PWB. As necessary, refer to: • 01D +3.3V Distribution RAP. • 01E +5V Distribution RAP. • 01F +12V Distribution RAP. • 01G +24V Distribution RAP. • 01B 0V Distribution RAP. Check that the CCD PWB/Scanner PWB ribbon cable 1, PL 14.15 Item 15 and CCD PWB/ Scanner PWB ribbon cable 2, PL 14.15 Item 23 are undamaged and correctly connected. Go to Flag 1. Check the wiring between P/J135 and P/J136 on the power distribution PWB in the SBC PWB module, and P/J920 on the scanner PWB. Repair as necessary or install a new SBC PWB/DADH comms/scanner power harness, PL 14.15 Item 5. Inspect the calibration strips on the front underside of the CVT glass and document glass. The calibration strips are undamaged. Y↓N→Install a new CVT glass, PL 14.20 Item 4 and/or a new document glass, PL 14.20 Item 5. Clean the white CVT strips, under the front edges of the document glass and the CVT glass, using a cleaning cloth dampened with film remover, PL 26.10 Item 4. Re-assemble the parts. If the fault persists, install new components as necessary: • Scan carriage ribbon cable, PL 14.15 Item 10. • Scanner PWB, PL 14.15 Item 4. • Scanner, PL 14.20 Item 1. Exposure Lamp Check CAUTION When measuring voltages of the scanner PWB, take special care not to short any two pins together. b. Remove the document size sensor cover. Go to Flag 2 and check the +24V at P/J926 on the scanner PWB (W/TAG 150), between pins 6 and 3. If +24V cannot be measured, check that there is no short circuit between P/J926, pins 6 and 3. As necessary install new components: • Scanner PWB, PL 14.15 Item 4. • Scan carriage ribbon harness, PL 14.15 Item 10. c. Measure the lamp enable signal between P/J926 pin 4 on the scanner PWB (W/ TAG 150) and the chassis, and enter the dC330 output code 14-005. The signal should change from +24V to 0V. If the signal does not change, install a new scanner PWB W/TAG 150, PL 14.15 Item 4. Go to Flag 3. Check the wiring between P/J1 on the exposer lamp inverter and P/J926 on the scanner PWB. Go to Flag 4. Check the wiring between the exposure lamp, PL 14.15 Item 9 and P/J2 on the exposure lamp inverter, NOTE: The fuse of the exposure lamp inverter is not replaceable Check the fuse in the exposure lamp inverter, see above note. If necessary, install new components: • Scan carriage ribbon cable, PL 14.15 Item 10. • Exposure lamp inverter PWB, PL PL

← Xem tất cả mã lỗi Xerox WorkCentre 5765

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie