Description: Single Board Controller PWB to IOT PWB Error RAP 03-300 The single board controller PWB to IOT communications have failed. 03-306 The IOT PWB has received an inappropriate print command from the single board controller PWB. 03-461 A speed mismatch has been detected between the single board controller PWB and the IOT PWB, in the NVM settings. 03-482 The single board controller PWB has failed to receive a +24V on signal from the IOT PWB. 03-805 The IOT PWB has received an un-recognized message from the single board controller PWB. 03-870 The IOT PWB cannot be recognized by the single board controller PWB.
Remedy: 1. Switch off the machine, GP 14. Ensure all the connectors on the single board controller PWB, PL 3.24 Item 3 and the IOT PWB, PL 1.10 Item 2 are correctly and securely seated. Switch on the machine, GP 14. 2. If the fault was detected during a software upgrade, go to Flag 1. Check P/J107 on the single board controller PWB. Re-load the software set, GP 4 Machine Software. 3. Perform OF7 IOT PWB Diagnostics RAP. 4. Go to Flag 2. Check the wiring, GP 7. If necessary, install a new single board controller PWB module / LVPS / IOT PWB harness, PL 3.24 Item 14. 5. 03-461 Only: Go to the OF7 IOT PWB Diagnostics RAP. Check CR 27 for an indication of NVM Test Failure. 6. Install a new IOT PWB, PL 1.10 Item 2. Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed. 7. Install a new single board controller PWB, PL 3.24 Item 3.