Mã lỗi 03-397 — Xerox WorkCentre 5775

Code: 03-397

Description: Main Motor Not Controlled RAP 03-397 The IOT software has detected that the main motor is not being controlled. The software that monitors the main motor and the photoreceptor motor was not reset within the expected time.
Remedy: Ensure that the connectors that follow are securely connected: • IOT PWB, PL 1.10 Item 2. • LVPS and base module, PL 1.10 Item 3. • Main drive motor and PWB, (35-55 ppm) PL 4.15 Item 6 or (65-90 ppm) PL 4.10 Item 6. The fault is still present. Y↓N→Perform SCP 6 Final Actions. Go to Flag 1 and Flag 2. Check the wiring, GP 7. The wiring is good. Y↓N→Repair the wiring, GP 7. Go to Flag 1. Check the voltages at P/J16, pins 1 and 2 on the LVPS. The voltages are correct. Y↓N→As necessary, refer to: • 01B 0V Distribution RAP. • 01G +24V Distribution RAP. Go to Flag 2. Measure the voltage at P/J3 pin 3, on the IOT PWB. Enter dC330 code 04-010, Main Motor On. Stack the photoreceptor motor code, 09-010. The voltage changes from high to low and the main motor runs. Y↓N→Perform the OF7 IOT PWB Diagnostics RAP. If necessary, install new components: • IOT PWB, PL 1.10 Item 2. • Main drive motor and PWB, (35-55 ppm) PL 4.15 Item 6 or (65-90 ppm) PL 4.10 Item 6. Reload the software, GP 4, Machine Software. If necessary, install new components: • Perform the OF7 IOT Diagnostics RAP before installing a new IOT PWB, PL 1.10 Item 2. • Main drive motor and PWB, (35-55 ppm) PL 4.15 Item 6 or (65-90 ppm) PL 4.10 Item 6.

← Xem tất cả mã lỗi Xerox WorkCentre 5775

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie