Description: Inserter Bottom Plate RAP 11-056-171 The inserter bottom plate has failed to return to the home position. 11-057-171 The inserter bottom plate has failed to lift.
Remedy: shows the location of the components. Enter dC330, code 11-078 for the inserter motor. The motor runs. Y↓N→Go to Flag 5 and Flag 6. Check the wiring from the motor to the HVF control PWB. Repair as necessary. Check the Inserter motor, MOT-078. Refer to: • GP 10 How to Check a Motor. • P/J701, HVF Control PWB • P/J4, P/J12, Inserter PWB • 11A-171 HVF Power Distribution RAP. Install new components as necessary: • Inserter Motor, MOT 11-078, PL 11.181 Item 1. • HVF control PWB, PL 11.157 Item 2. Enter dC330, code 11-156 for the inserter bottom plate sensor and actuate the sensor. The display changes. Y↓N→Go to Flag 1 and Flag 2. Check the wiring from the sensor to the HVF control PWB. Repair as necessary. Check the bottom plate sensor, Q11-156. Refer to: • GP 11 How to Check a Sensor. • P/J701, HVF Control PWB • 11A-171 HVF Power Distribution RAP. • P/J3, P/J4, Inserter PWB Install new components as necessary: • Bottom plate sensor, Q11-156, PL 11.175 Item 16. • HVF control PWB, PL 11.157 Item 2. Go to Flag 3 and Flag 4. Check the wiring from the IDG Pickup Sensor to the Inserter PWB. Check the IDG Pickup Sensor. Refer to: • GP 11 How to Check a Sensor. • P/J701, HVF Control PWB • P/J7, P/J4, Inserter PWB Install new components as necessary: • IDG Pickup sensor, PL 11.179 Item 10. • HVF control PWB, PL 11.157 Item 2. Perform SCP 6 Final Actions.