Description: 1K LCSS Power Distribution RAP The 1K LCSS has an integral power supply providing +24V and +5V supplies to the 1K LCSS PWB. The AC power for the 1K LCSS power supply comes from the LVPS and base module of the machine.
Remedy: Close or cheat all the 1K LCSS interlocks. LED 2 on the 1K LCSS PWB is illuminated. Y↓N→Go to Flag 2. +24V is available at P/J1 between pins 1 and 2, also between pins 5 and 3. Y↓N→Disconnect P/J6. +24V is available at P/J6 between pins 1 and 2, also between pins 5 and 3 on the end of the harness. Y↓N→Go to Flag 1. Disconnect the 1K LCSS power cord from PJ22. ACL is available at PJ22 between pins 1 and 3 on the LVPS and base module. Y↓N→Go to the 01C AC Power RAP. Remove the 1K LCSS-120. Loosen the 2 screws and lift the power supply module away from the 1K LCSS frame. Go to Flag 1. Check the wiring between CN2 and P/J6. The wiring is good. Y↓N→Repair the wiring. Install a new power supply module, PL 11.124 Item 2. Perform the following: • Check for a short circuit or an overload in the wiring or components connected to the +24V on the 1K LCSS PWB. Refer to GP 7. • Perform the 11F-120 1K LCSS PWB Damage RAP. If necessary install a new 1K LCSS PWB, PL 11.124 Item 1. +24 V is available at P/J5 pin 3 on the 1K LCSS PWB. Y↓N→Go to the 11-300-120, 11-302-120, 11-303-120 Interlocks RAP. Perform the following: • Switch off the machine, GP 14. • Go to Flag 3. Disconnect all the +24V harnesses to components. • Check each harness for short circuits and overheating, GP 7. • Repair or install new components as necessary. • Monitor the voltage at P/J6 pin 1. Re-connect the circuits one at a time. Energize the re-connected components using dC330 control codes. • If the voltage drops below +22V, switch off the machine, GP 14. Re-check the component and harness for overheating or short circuits. Repair or install new components as necessary. +5V is available between TP3 and TP4 on the 1K LCSS PWB. Y↓N→Go to Flag 2. +5V is available at P/J1 between pins 4 and 6, also between pins 7 and 8. Y↓N→Disconnect P/J6. +5V is available at P/J6 between pins 4 and 6, also between pins 7 and 8 on the end of the harness. Y↓N→Go to Flag 1. Disconnect the 1K LCSS power cord from PJ22. ACL is available at PJ22 between pins 1 and 3 on the LVPS and base module. Y↓N→Go to the 01C AC Power RAP. Remove the 1K LCSS-120. Loosen the 2 screws and lift the power supply module away from the 1K LCSS frame. Go to Flag 1. Check the wiring between CN2 and P/J6. The wiring is good. Y↓N→Repair the wiring. Install a new power supply module, PL 11.124 Item 2. Perform the following: • Check for a short circuit or an overload in the wiring or components connected to the +24V on the 1K LCSS PWB. Refer to GP 7. • Perform the 11F-120 1K LCSS PWB Damage RAP. If necessary install a new 1K LCSS PWB, PL 11.124 Item 1. Perform the 11F-120 1K LCSS PWB Damage RAP. If necessary install a new 1K LCSS PWB, PL 11.124 Item 1. The +24V and +5V supplies on the 1K LCSS PWB are good.