Remedy: shows the component location. Go to Flag 1. Check the voltages at P/J136 on the power distribution PWB. As necessary, refer to: • 01D +3.3V Distribution RAP. • 01E +5V Distribution RAP. • 01G +24V Distribution RAP. • 01B 0V Distribution RAP. Remove the following components, • DADH. • Document glass. • Document size sensor cover. Check the wiring between P/J136 on the power distribution PWB in the single board controller PWB module and P/J920 on the scanner PWB. Repair as necessary or install a new single board controller PWB/DADH comms/scanner power harness, PL 14.15 Item 5. Check that the input module angle sensor actuator is not damaged, if necessary, install a new actuator, PL 14.15 Item 21. Switch the machine off, then switch the machine on GP 14. The fault is still present Y↓N→Perform SCP 6 final actions. Reinstall the DADH. Enter the dC330 input code 14-310, Document Handler Angle Sensor and actuate the input module angle sensor, Q14-310 by opening and closing the DADH. The display changes. Y↓N→Go to Flag 2. Check the input module angle sensor, Q14-310. Refer to GP 11, How to Check a Sensor. Repair or install new components as necessary: • Input module angle sensor, PL 14.15 Item 16. • Scanner PWB, PL 14.15 Item 4. Reinstall the document size sensor cover. Raise the DADH, enter the dC330 input code 14-315, actuate the document size sensor 1, Q14-315 by placing a piece of paper above the sensor. Enter the dC330 input code 14-320 and repeat the test for document size sensor 2, Q14-320. The display changes for both sensors. Y↓N→Go to Flag 3. Check the document size sensors 1 and 2, refer to: • GP 11 How to Check a Sensor. NOTE: If necessary, temporarily install the document glass when checking the size sensors, to ensure that the document is the correct distance from the sensor. Repair or install new components as necessary: • Document size sensor, PL 14.15 Item 3. • Scanner PWB, PL 14.15 Item 4. Reassemble the scanner, then perform dC604 Registration Setup.