Mã lỗi 03-350, 03-351, 03-354 — Xerox WorkCentre 5790

Code: 03-350, 03-351, 03-354

Description: IOT to Tray 1 and Tray 2 PWB Error RAP 03-350 The IOT has detected no response from the tray 1 and 2 control PWB to the ping request. 03-351 Tray 1 and 2 control PWB has detected a feed buffer overflow. 03-354 Communications failure. Tray 1 and 2 control PWB has detected a communications failure.
Remedy: 1. Switch off the machine, GP 14. Ensure P/J9 and P/J271 are correctly and securely connected. 2. Go to Flag 1. Check the harness. Repair as necessary, GP 7. 3. Go to Flag 2. Check the +3.3V and 0V lines. Refer to: • P/J271 • 01D +3.3V Distribution RAP. • 01B 0V Distribution RAP. 4. Switch on the machine, GP 14. Perform OF7 IOT PWB Diagnostics RAP. 5. Re-load the software, GP 4 Machine Software. 6. Install new components as necessary: • Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL 1.10 Item 2. • Tray 1 and 2 control PWB, PL 7.10 Item 2.