Mã lỗi 09-375 — Xerox WorkCentre 5790

Code: 09-375

Description: Ambient Temperature Sensor Failure RAP 09-375 The average ambient temperature is out of limits.
Remedy: Enter dC330 code 09-375, ambient temperature sensor, Q09-375. Press start. Observe the displayed state of Q09-375.. Open the left hand door, gently blow on the temperature sensor PWB. Observe again the displayed state of Q09-375. The displayed state has changed. Y↓N→Go to Flag 1. Check for +5V at P/J7 pin 3 on the IOT PWB. +5V is present. Y↓N→Go to: • 01E +5V Distribution RAP. • 01B 0V Distribution RAP. Go to Flag 1. Disconnect P/J46. Check for +5V at P/J46, pin 1. +5V is present. Y↓N→Check the wiring between P/J7 on the IOT PWB and P/J46, GP 7. Repair the wiring as necessary. Install a new relative humidity sensor / ambient temperature sensor, (35 ppm) PL 9.22 Item 4, (40-90 ppm) PL 9.20 Item 4. If the fault persists, perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL 1.10 Item 2. The ambient temperature sensor is working correctly. If the fault is intermittent, perform the steps that follow: • Check the wiring, GP 7. Repair if necessary. • Make sure that the P/Js are correctly and securely connected, GP 11.

← Xem tất cả mã lỗi Xerox WorkCentre 5790