Description: IOT Exit Sensor RAP 310-120-00 The lead edge of the paper failed to reach the IOT exit sensor within the correct time after the trail edge at the fuser exit switch for an inverted sheet. 310-121-00 The lead edge of the paper failed to reach the IOT exit sensor within the correct time after the trail edge at the fuser exit switch for an non inverted sheet. 310-126-00 The trail edge of the paper failed to clear the IOT exit sensor within the correct time
Remedy: NOTE: Ensure that the door interlock switch is cheated when checking +24V components. Enter dC330 code 010-120 IOT exit sensor, Q10-120. Press Start. Manually actuate the sensor. The display changes. Y↓N→Go to Flag 1 (45 to 55ppm) or Flag 5 (65 to 90ppm). Check Q10-120. Refer to: • GP 11 How to Check a Sensor. • P/J5, IOT PWB. • 301D +3.3V Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new IOT exit sensor, PL 10.11 Item 13. If the fault remains, perform the OF7 IOT PWB Diagnostics RAP. Enter dC330 code 010-050 inverter nip solenoid, SOL10-050. Press Start. The solenoid energises. Y↓N→Go to Flag 2 (45 to 55ppm) or Flag 6 (65 to 90ppm). Check SOL10-050. Refer to: • GP 12 How to Check a Solenoid or Clutch. • P/J5, IOT PWB. • P/J17, LVPS. • Fuse, PL 1.10 Item 9, GP 7. • 301G +24V Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new inverter nip solenoid, PL 10.11 Item 6. If the fault remains, perform the OF7 IOT PWB Diagnostics RAP. Enter dC330 code 010-045 inverter path solenoid, SOL 10-045. Press Start. The solenoid energizes. Y↓N→Go to Flag 3 (45 to 55ppm) or Flag 7 (65 to 90ppm). Check SOL 10-045. Refer to: • GP 12 How to Check a Solenoid or Clutch. • P/J5, IOT PWB • P/J17, LVPS. • Fuse, PL 1.10 Item 9, GP 7. • 301G +24V Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new inverter path solenoid, PL 10.11 Item 14. If the fault remains, perform the OF7 IOT PWB Diagnostics RAP. Enter dC330 code 010-030 inverter motor, MOT10-030. Press Start. The jam clearance knob, 2B, PL 10.15 Item 13, is stationary and the motor can be heard. Y↓N→The jam clearance knob, 2B, PL 10.15 Item 13, rotates counterclockwise. Y↓N→Go to Flag 4. Check MOT10-030. Refer to: • GP 10 How to Check a Motor. • P/J4, IOT PWB • P/J45, P/J55 inverter motor driver PWB • 301G +24V Distribution RAP • 301E +5V Distribution RAP. • 301B 0V Distribution RAP. Install new components as necessary: • Inverter motor, PL 10.14 Item 13. • Inverter motor driver PWB, PL 10.11 Item 22. If the fault remains, perform the OF7 IOT PWB Diagnostics RAP. Install a new inverter motor driver PWB, PL 10.11 Item 22. Check the following components, refer to GP 7: • Idler rolls, PL 10.12 Item 15. • Upper baffle, PL 10.12 Item 22. • Decurler roll, PL 10.13 Item 8. • Nip split shaft assembly, PL 10.11 Item 4. • The drive gear on the fuser module, (45-55 ppm) PL 10.8 Item 1 or (65-90 ppm) PL 10.10 Item 1. • The fuser drive gear on the main drives module, (45-55 ppm) PL 40.17 Item 10 or (65-90 ppm) PL 40.12 Item 10. • Check the IOT exit sensor mounting bracket, PL 10.11 Item 10. The bracket holds the IOT exit sensor in the correct position, PL 10.11 Item 13. If the fault remains, the +24V supply from the LVPS may be faulty. Perform the 301L LVPS Checkout RAP.