Mã lỗi 310-322-00, 310-324-00, 310-325-00, 310-330-00, 310-370-00 — Xerox WorkCentre 5845

Code: 310-322-00, 310-324-00, 310-325-00, 310-330-00, 310-370-00

Description: Fuser Under Temperature RAP 310-322-00 Under temperature during standby mode, the thermistor reading is not within the target temperature range 310-324-00 under temperature during run mode, the thermistor reading is not within the target temperature range 310-325-00 The fuser control task watchdog timer has not been reset within a specified period. 310-330-00 The initial fuser temperature rise was not achieved within 30 seconds from the start of warm up mode or the standby temperature was not reached within 150 seconds. 310-370-00 During power save mode, the thermistor reading is not within the target value, after the fuser has cooled to the power save temperature.
Remedy: Switch off the machine GP 14. Remove the fuser module and check the continuity between pin 1 and pin 2 and between pin 3 and pin 4 on the fuser module connector. There is continuity. Y↓N→Install a new fuser module, (45-55 ppm) PL 10.8 Item 1 or (65-90 ppm) PL 10.10 Item 1. Install the fuser module. Disconnect PJ24. Go to Flag 2 and check for continuity between pin 1 and 3 and between pins 4 and 6 at the harness end. There is continuity. Y↓N→Check the fuser connector assembly. If necessary, install a new fuser connector assembly, (45-55 ppm) PL 40.15 Item 9 or (65-90 ppm) PL 40.10 Item 9. WARNING Take care when measuring AC mains (line) voltage. Electricity can cause death or injury. NOTE: The voltage will be 100% of the ACL voltage when the machine is switched on from cold and pulse between 60% and 100% during standby. Connect PJ24. Go to Flag 2. Check for ACL at PJ24. Switch on the machine, GP 14. ACL is available at PJ24 between pin 1 and 3, and between pin 4 and 6. Y↓N→Perform the OF7 IOT PWB Diagnostics RAP. If the fault remains, perform the 301L LVPS Checkout RAP. Go to Flag 1. With the fuser cold, check for +2.9V at pin 1 and at pin 2. +2.9V is available at both pins. Y↓N→Go to Flag 1. Check the wiring and connectors. Refer to: • P/J35, IOT PWB. • 301D +3.3 V Distribution RAP. • 301B 0V Distribution RAP Perform the OF7 IOT PWB Diagnostics RAP. If the fault persists, install a new fuser module, (45-55 ppm) PL 10.8 Item 1 or (65-90 ppm) PL 10.10 Item 1. If the fault persists, install a new fuser module, (45-55 ppm) PL 10.8 Item 1 or (65-90 ppm) PL 10.10 Item 1.

← Xem tất cả mã lỗi Xerox WorkCentre 5845

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie