Description: Sheet Late to Bin 1 RAP 311-140-00-110 The leading edge of the sheet is late to the 2nd to top exit sensor, Q11-140. 311-142-00-110 The trailing edge of the sheet is late to the 2nd to top exit sensor, Q11-140.
Remedy: NOTE: All 2K LCSS interlocks must be made to supply +24V to the motors.. Enter dC330 code 011-001 to energize the transport motor 2, MOT11-001. MOT11- 110 runs. Y↓N→Go to Flag 3. Check MOT11-001. Refer to: • 311G-110 2K LCSS PWB Damage RAP. • GP 10, How to check a motor. • P/J309, 2K LCSS PWB. • 311D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Transport motor 2, PL 11.22 Item 5. • 2K LCSS PWB, PL 11.26 Item 1. Enter dC330 code 011-002 to energize the diverter solenoid, SOL11-002. The diverter solenoid energizes. Y↓N→Go to Flag 4. Check SOL11-002. Refer to: • 311G-110 2K LCSS PWB Damage RAP. • GP 12, How to Check a Solenoid or Clutch. • P/J306, 2K LCSS PWB. • 311D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Diverter gate solenoid, PL 11.22 Item 12. • 2K LCSS PWB, PL 11.26 Item 1.. Enter dC330 code 011-140, actuate the 2nd to top exit sensor, Q11-140. The display changes. Y↓N→Go to Flag 1. Check Q11-140. Refer to: • 311G-110 2K LCSS PWB Damage RAP. • GP 11, How to Check a sensor. • P/J313, 2K LCSS PWB. • 311D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • 2nd to top exit sensor, PL 11.23 Item 4. • 2K LCSS PWB, PL 11.26 Item 1. Enter dC330 code 011-000 to energize the transport motor 1, MOT11-000. MOT11-000 runs. Y↓N→Go to Flag 2. Check MOT11-000. Refer to: • 311G-110 2K LCSS PWB Damage RAP. • GP 10, How to Check a Motor. • P/J305, 2K LCSS PWB. • 311D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Transport motor 1, PL 11.14 Item 2. • 2K LCSS PWB, PL 11.26 Item 1. If the fault is still present, perform the 311-319-00-110 Rear Tamper Move Failure RAP. NOTE: A software problem can cause the machine to incorrectly display the fault code 11-142- 110.