Description: Ejector Movement Failure RAP 311-320-00-150 The ejector is not at the home position. 311-322-00-150 The ejector fails to perform a cycle of operation. NOTE: A cycle of operation for the ejector is to cycle from the home position to the out position and back to the home position.
Remedy: NOTE: All LVF BM interlocks must be made to supply +24V to the motors. Enter dC330, code 011-322 actuate the ejector out sensor, Q11-322. The display changes. Y↓N→Go to Flag 2. Check Q11-322. Refer to: • GP 11 How to Check a Sensor. •. • P/J304, LVF PWB. • 311D-150 LVF BM Power Distribution RAP. Repair or install new components as necessary: • Ejector out sensor, PL 11.66 Item 3. • LVF PWB, PL 11.90 Item 8 Enter dC330, code 011-320, actuate the ejector home sensor, Q11-320. The display changes. Y↓N→Go to Flag 1. Check Q11-320. Refer to: • GP 11 How to Check a Sensor. •. • P/J304, LVF PWB. • 311D-150 LVF BM Power Distribution RAP. Repair or install new components as necessary: • Ejector home sensor, PL 11.66 Item 3. • LVF PWB, PL 11.90 Item 8. Enter dC330, code 011-023 ejector cycle, check the operation of the ejector motor MOT11- 020. The ejector motor runs. Y↓N→Go to Flag 3. Check the ejector motor, MOT11-020. Refer to: • GP 10, How to Check a Motor. •. • P/J303, LVF PWB. • 311D-150 LVF BM Power Distribution RAP. Repair or Install new components as necessary: • Ejector assembly, PL 11.66 Item 1. • LVF PWB, PL 11.90 Item 8. Enter dC330, code 011-023 ejector cycle, check the ejector cycles. Stack the code 011-320 ejector sensor home, then cycle the ejector. Stack the code 011-322 ejector sensor out, then cycle the ejector. The ejector actuates the ejector home sensor and the ejector out sensor. Y↓N→Refer to GP 7, check the following components, install new components as necessary; • Pulley drive gear, PL 11.66 Item 8. • Ejector belt, PL 11.66 Item 5. The ejector cycles noisily, colliding with the end stops. Y↓N→Check the stapler to ensure the staples are correctly formed. Mis-formed staples can cause the set to hang in the stapler causing ejector movement failures. The staples are correctly formed. Y↓N→Clear the staple head of any mis-formed staples, then check the operation of the stapler. If necessary, install a new staple head unit, PL 11.68 Item 5. If the ejector is still not moving, install a new ejector assembly, PL 11.66 Item 1. Perform SCP 5 Final Actions. Enter dC330, code 011-177, actuate the ejector motor encoder sensor, Q11-177. The display changes. Y↓N→Go to Flag 4. Check Q11-177. Refer to: • GP 11 How to Check a Sensor. •. • P/J304, LVF PWB. • 311D-150 LVF BM Power Distribution RAP. Repair or install new components as necessary: • Ejector motor encoder sensor, Q11-096, PL 11.66 Item 3. • LVF PWB, PL 11.90 Item 8.