Mã lỗi 311-377-00-150 — Xerox WorkCentre 5845

Code: 311-377-00-150

Description: LVF BM Stapling Failure RAP 311-377-00-150 Staples in the staple head unit are not primed.
Remedy: . Enter dC330, code 011-361, actuate the SH 1 paper sensor, Q11-361. The display changes. Y↓N→Go to Flag 1. Check Q11-361. Refer to: • GP 11, How to Check a Sensor. • P/J308, LVF PWB. • 311D-150 LVF BM Power Distribution RAP. Repair or install new components as necessary: • SH 1 paper sensor, PL 11.68 Item 4. • LVF PWB, PL 11.90 Item 8. NOTE: If the SH1 priming sensor does not see staples in the primed position, the staple head cycles a number of times to prime the staple head. This occurs when the LVF BM interlocks are made. Follow the customer instruction label inside the LVF BM front door to remove the staple cartridge, slide out the top sheet of staples from the cartridge, to expose a fresh sheet of staples on the top of the stack. Ensure the forming plate is fully closed. Install the staple cartridge and close the door. The stapler will now cycle a few times to feed and prime the new sheet of staples. Open the door and remove the staple cartridge. Examine the sheet of staples that have been fed to the staple forming part of the stapler, by opening the forming plate. The first two staples have been partially formed. Y↓N→Install a new staple cartridge, PL 11.68 Item 7 and repeat the check. If the first two staples are not partially formed, install a new staple head unit, PL 11.68 Item 5. Perform SCP 5 Final Actions Install a new staple head unit, PL 11.68 Item 5. Perform SCP 5 Final Actions.

← Xem tất cả mã lỗi Xerox WorkCentre 5845

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie