Mã lỗi 361-020-00 — Xerox WorkCentre 5845

Code: 361-020-00

Description: ROS Motor Failure RAP 361-020-00 This fault code has two failure modes: • The ROS motor ready signal was not received by the IOT PWB within the set time of the ROS being powered on. • The IOT PWB recognizes a change of state of the ROS motor ready signal during operation.
Remedy: Switch off the machine, then switch on the machine, GP 14. The 361-020 fault still exists. Y↓N→Perform SCP 5 Final Actions. Enter the dC330 output code 061-020 and listen for the ROS motor. The ROS motor gives a distinctive ascending frequency sound, of a short duration (5 to 6 seconds) during transition from standby to run. Y↓N→The xerographic module is fully home and the front door is fully closed or the front door interlock is cheated. Y↓N→Correct the condition. If necessary go to the 301-300-00 Front Door Open RAP. Go to Flag 1. Check the following voltages at P/J18 on the LVPS: • +24V between pins 1 and 2. • +3.3V between pins 3 and 4. The voltages are good. Y↓N→Go to the relevant RAP: • 301B 0V Distribution RAP, refer to the 3.3V return and 24V return. • 301D +3.3V Distribution RAP. • 301G +24V Distribution RAP. Enter the dC330 output code 061-020 to run the ROS motor. Go to Flag 2. 0V is available at P/J2 pin 1 on the IOT PWB. Y↓N→Go to Flag 3. 0V is available at P/J2 pin 6 on the IOT PWB. Y↓N→Perform the OF7 IOT PWB Diagnostics RAP. NOTE: To disconnect P/J1 and P/J2 the ROS must be removed from the machine, refer to. The ROS PWB may not be marked with the correct PJ numbers, where P/J1 and P/J2 are connected. P/J1 can be identified as a four way power harness. P/J2 can be identified as a seven way signal harness. Go to Flag 1, Flag 2 and Flag 3. Disconnect P/J1 and P/J2. Check the wiring. The wiring is good. Y↓N→Repair the wiring. Install a new ROS, PL 60.10 Item 4. Perform the OF7 IOT PWB Diagnostics RAP. Go to Flag 2. 0V is available at P/J2 pin 1. Y↓N→NOTE: To disconnect P/J1 and P/J2 the ROS must be removed from the machine. The ROS PWB may not be marked with the correct PJ numbers, where P/J1 and P/J2 are connected. P/J1 can be identified as a four way power harness. P/J2 can be identified as a seven way signal harness. Check the continuity of the seven way signal harness between P/J2 on the ROS and P/ J2 on the IOT PWB. The harness is good. Y↓N→Install a new ROS power distribution/communication harness, PL 60.10 Item 5. Install a new ROS, PL 60.10 Item 3. If the fault condition persists, perform the following: • Check the condition of the associated wiring and connectors. Repair the wiring or install new components as necessary. • Install a new ROS, PL 60.10 Item 4. • Perform the OF7 IOT PWB Diagnostics RAP.

← Xem tất cả mã lỗi Xerox WorkCentre 5845

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie