Description: SPDH Hotline Error RAP 362-783-00 SPDH side 1 hotline error. 366-783-00 SPDH side 2 hotline error.
Remedy: Switch off the machine, then switch on the machine, GP 14. The fault is still present. Y↓N→Perform SCP 5 Final Actions. Re-load the software set, GP 4 Machine Software. The fault is still present. Y↓N→Perform SCP 5 Final Actions. Go to Flag 1. Disconnect then check the harness and connectors P/J460 on the SPDH PWB and P/J417 on the scanner PWB. The harness and connectors are good. Y↓N→Repair the harness and connectors. Install new components as necessary: • SPDH PWB, PL 5.10 Item 5 • Scanner PWB, PL 60.20 Item 6 Re-install the harness, then check the operation of the machine. The fault is still present. Y↓N→Perform SCP 5 Final Actions. Go to Flag 2. Disconnect then check the harness and connectors P/J410 on the scanner PWB and P/J140 on the power distribution PWB. The harness and connectors are good. Y↓N→Repair the harness and connectors. Install new components as necessary: • Scanner PWB, PL 60.20 Item 6 • Power distribution PWB, PL 3.22 Item 1 Re-install the harness, then check the operation of the machine. The fault is still present. Y↓N→Perform SCP 5 Final Actions. Go to Flag 3. Disconnect then check the harness and connectors P/J141 on the power distribution PWB and P/J266 on the SBC PWB. The harness and connectors are good. Y↓N→Repair the harness and connectors. Install new components as necessary: • SBC PWB, PL 3.22 Item 3 • Power distribution PWB, PL 3.22 Item 1 Re-install the harness, then check the operation of the machine. The fault is still present. Y↓N→Perform SCP 5 Final Actions. Go to the 305A Document Size Sensors RAP and check document size sensor 1 and document size sensor 2. The fault is still present. Y↓N→Perform SCP 5 Final Actions. Check the appropriate sensor: • For 362-783-00 faults check the reg sensor. Perform the RAP 305-340-00, 305-341-00 SPDH Reg Sensor Failure. • For 366-783-00 faults check the side 2 reg sensor. Perform the RAP 305-342-00, 305- 343-00 SPDH Side 2 Reg Sensor Failure. The fault is fixed. Y↓N→Perform 303D SBC PWB Diagnostics RAP. Perform SCP 5 Final Actions.