Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 310-132-00, 310-133-00, 310-134-00 — Xerox WorkCentre 5855

Code: 310-132-00, 310-133-00, 310-134-00

Description: Lead Edge Late to Inverter Sensor RAP 310-132-00 The lead edge of the paper failed to actuate the inverter sensor within the correct time after the fuser exit switch is made, for a simplex sheet. 310-133-00 The lead edge of the paper failed to actuate the inverter sensor within the correct time after the fuser exit switch is made, for a duplex 1 sheet. 310-134-00 The lead edge of the paper failed to actuate the inverter sensor within the correct time after the fuser exit switch is made, for a duplex 2 sheet. NOTE: The inverter sensor is only used on 65-90 ppm machines.
Remedy: NOTE: The door interlock switch must be cheated when checking +24V components. Enter dC330 code 010-100 fuser exit switch, S10-100. Press Start. Manually actuate the switch with a piece of paper. The display changes. Y↓N→Go to Flag 1. Check S10-100. Refer to: • GP 13 How to Check a Switch. • P/J35, IOT PWB. • 301D +3.3V Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new fuser exit switch, PL 10.10 Item 11. If the fault remains, perform the OF7 IOT PWB Diagnostics RAP. Enter dC330 sensor code 010-105 inverter sensor, Q10-105. Press Start. Use a piece of paper to actuate the sensor. The display changes. Y↓N→Go to Flag 2. Check Q10-105. Refer to: • GP 11. How to Check a Sensor. • P/J61, IOT PWB • 301E +5V Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new inverter sensor, PL 10.12 Item 19. If the fault remains, perform the OF7 IOT PWB Diagnostics RAP. Check the following components, refer to GP 7: • The drive gear on the fuser module, PL 10.10 Item 1. • The fuser drive gear on the main drives module, PL 40.12 Item 10. • Fuser web motor and the fuser web, refer to the 310A Fuser Web Motor RAP. • Drives between inverter decurler assembly and the main drives module, PL 10.15. • Post fuser exit roller, PL 10.12 Item 9. NOTE: Excessive post fuser exit roll wear causes buckle between the fuser and the inverter decurler assembly. This can cause severe ripple on the trail edge of A3 (11x17 inch) sheet and paper jams. • Upper baffle, PL 10.12 Item 22. • Baffle guide, PL 10.13 Item 3.

← Xem tất cả mã lỗi Xerox WorkCentre 5855

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie