Description: Bin 1 Movement Failure RAP 311-030-00-120 Bin 1 fails to move. NOTE: The home position of bin 1 is when bin 1 is actuating the bin 1 upper limit switch. See the final actions at the end of the procedure. Two sensors and two switches monitor the level of paper in bin 1 and the position of the tray • The bin 1 upper level sensor detects the top of the paper stack in bin 1. • The bin 1 90% full sensor detects when the tray has descended to a position where the tray is 90% full. • Bin 1 upper limit switch, S11-334. • Bin 1 lower limit switch, S11-335.
Remedy: NOTE: All 1K LCSS interlocks must be made to supply +24V to the motors. Remove the 1K LCSS rear cover. Enter dC330 code 011-336, bin 1 motor encoder sensor Q11-336. Slowly rotate the encoder disk by hand. The display changes. Y↓N→Go to Flag 2. Check Q11-336. Refer to: • 311F-120 1K LCSS PWB Damage RAP. • GP 11 How to Check a Sensor. • P/J8, 1K LCSS PWB • 311C-120 1K LCSS Power Distribution RAP. Install new components as necessary: • Bin 1 motor encoder sensor, PL 11.106 Item 11. • 1K LCSS PWB, PL 11.124 Item 1. Enter dC330 code 011-033, bin 1 elevator motor, MOT11-030. Bin 1 cycles down and up. Y↓N→Go to Flag 1. Check MOT11-030. Refer to: • 311F-120 1K LCSS PWB Damage RAP. • GP 10 How to Check a Motor. • P/J12, 1K LCSS PWB • 311C-120 1K LCSS Power Distribution RAP. Install new components as necessary: • Bin 1 elevator motor, PL 11.106 Item 8. • 1K LCSS PWB, PL 11.124 Item 1.. Enter dC330 code 011-332, bin 1 upper level sensor, Q11-332. Actuate Q11-332. The display changes. Y↓N→Go to Flag 3. Check Q11-332. Refer to: • 311F-120 1K LCSS PWB Damage RAP. • GP 11 How to Check a Sensor. • P/J2, 1K LCSS PWB • 311C-120 1K LCSS Power Distribution RAP. Install new components as necessary: • Bin 1 upper level sensor, PL 11.106 Item 5. • 1K LCSS PWB, PL 11.124 Item 1.. Enter dC330 code 011-334, bin 1 upper limit switch, S11-334. Actuate S11-334. The display changes. Y↓N→Go to Flag 4. Check S11-334. Refer to: • 311F-120 1K LCSS PWB Damage RAP. • GP 13 How to Check a Switch. • P/J5, 1K LCSS PWB • 311C-120 1K LCSS Power Distribution RAP. Install new components as necessary: • Bin 1 upper limit switch, PL 11.106 Item 3. • 1K LCSS PWB, PL 11.124 Item 1. Enter dC330 code 011-335, bin 1 lower limit switch, S11-335. Actuate S11-335. The display changes. Y↓N→Go to Flag 5. Check S11-335. Refer to: • 311F-120 1K LCSS PWB Damage RAP. • GP 13 How to Check a Switch. • P/J4, 1K LCSS PWB. • 311C-120 1K LCSS Power Distribution RAP. •-110 1K LCSS Un-docking. Install new components as necessary: • Bin 1 lower limit switch, PL 11.106 Item 11. • 1K LCSS PWB, PL 11.124 Item 1. Enter dC330 code 011-331, bin 1 90% full sensor, Q11-331. Actuate Q11-331. The display changes. Y↓N→Go to Flag 6. Check Q11-331. Refer to: • 311F-120 1K LCSS PWB Damage RAP. • GP 11 How to Check a Sensor. • P/J2, 1K LCSS PWB. • 311C-120 1K LCSS Power Distribution RAP. Install new components as necessary: • Bin 1 90% full sensor, PL 11.106 Item 5. • 1K LCSS PWB, PL 11.124 Item 1. As final actions, check the following sequence of operation: • When bin 1 is empty and at the top, bin 1 upper limit switch, S11-334 is actuated and the bin 1 upper level sensor, Q11-332 is de-actuated. • Paper is delivered to the tray until the bin 1 upper level sensor, Q11-332 is actuated. • The motor lowers the tray until the bin 1 upper level sensor, Q11-332 is de-actuated. • When the tray is emptied, the tray returns to the home position. In the home position the bin one upper limit switch, S11-334 is actuated.