Description: Tray 6 Elevator Lower Failure RAP 376-101-00 A signal was not detected by the encoder when the elevator motor was driving down.
Remedy: Ensure the cable holder is not trapped behind the elevator motor bracket. The cable holder is correctly positioned. Y↓N→Reposition the cable holder so that it does not become trapped behind the elevator motor bracket. Open, then close the tray 6 door. The tray moves down. Y↓N→Enter dC330 code 076-300 front door interlock switch, S76-300. Press Start. Manually toggle the door interlock switch. The display changes. Y↓N→Go to Flag 1. Check S76-300. Refer to: • GP 13 How to Check a Switch. • P/J507, Tray 6 control PWB. • 301E +5V Distribution RAP. • 301B 0V Distribution RAP. Install new components as necessary: • Front door interlock switch, PL 70.60 Item 6. • Tray 6 control PWB, PL 70.68 Item 8. Enter dC330 code 076-335 stack down sensor, Q76-335. Press Start. Manually activate the stack down sensor. The display changes Y↓N→Go to Flag 2. Check Q76-335. Refer to: • GP 11 How to Check a Sensor. • P/J505, Tray 6 control PWB. • 301E +5V Distribution RAP. • 301B 0V Distribution RAP. Install new components as necessary: • Stack down sensor, PL 70.68 Item 9. • Tray 6 control PWB, PL 70.68 Item 8. Check the voltage at PJ504 pin 6, Flag 3. Manually actuate the tray down limit switch, S76-415, by pressing the plate under the paper tray. The voltage changes. Y↓N→Go to Flag 3. Check S76-415. Refer to: • GP 13 How to Check a Switch. • P/J504, Tray 6 control PWB. • 301G +24V Distribution RAP. • 301B 0V Distribution RAP. Install new components as necessary: • Tray down limit switch, PL 70.70 Item 2. • Tray 6 control PWB, PL 70.68 Item 8. Enter dC330 code 076-340 elevator motor encoder sensor, Q76-340. Press Start. Manually lift the elevator motor to activate the sensor. The display changes Y↓N→Go to Flag 4. Check Q76-340. Refer to: • GP 11 How to Check a Sensor. • P/J506, Tray 6 control PWB. • 301E +5V Distribution RAP. • 301B 0V Distribution RAP. Install new components as necessary: • Elevator motor encoder sensor, PL 70.68 Item 5. • Tray 6 control PWB, PL 70.68 Item 8. Enter dC330 code 076-011 to lower the elevator motor, MOT76-010. Press Start. The motor runs Y↓N→Go to Flag 5. Check MOT76-010. Refer to: • GP 10 How to Check a Motor. • P/J504, Tray 6 control PWB. • 301G +24V Distribution RAP. • 301B 0V Distribution RAP Install new components as necessary: • Elevator motor, PL 70.68 Item 4. • Tray 6 control PWB, PL 70.68 Item 8. The elevator motor is operating correctly. Perform ADJ 70.5 Tray 6 Stack Height Sensor and Retard Shield, then perform SCP 5 Final Actions. The elevator motor is operating correctly. Perform ADJ 70.5 Tray 6 Stack Height Sensor and Retard Shield, then perform SCP 5 Final Actions.