Code: 393-360-00 ... 393-363-00
Description: Toner Concentration Sensor Failure RAP 393-360-00 The toner concentration sensor has registered a reading outside the range, +0.75V to +4.55V for three consecutive sheets. 393-361-00 The toner concentration sensor is reading high. This indicates that the toner concentration (TC) is low. 393-362-00 The toner concentration sensor is reading low. This indicates that the toner concentration (TC) is high. 393-363-00 This code is generated by the following factors: • The developer is not positioned correctly against the xerographic module. • The toner concentration is low. • The machine is being installed. • On the fifth consecutive occurrence. GUI message - TONER CONTROL FAILURE
Remedy: NOTE: The door interlock switch must be cheated when checking +24V components. Enter dC330 42-010, to run the main drive motor. Go to Flag 1. Read the voltage at P/J93 pin 8 while the main drive motor is running. The voltage is outside the range of +0.7V to +4.5V. Y↓N→Check the steps that follow: • Refer to GP 7. Check the wiring between P/J93 and P/J6 on the IOT PWB. • Refer to the 301B 0V Distribution RAP. • Ensure the developer module is correctly installed. The voltage at P/J93, pin 8, is less than +0.75V. Y↓N→The voltage is greater than +4.5V. Check the wiring, GP 7. Go to Flag 3. +24V is present at P/J93, pin 2. Y↓N→Disconnect P/J93. +24V is present at the harness end of P/J93, pin 2. Y↓N→Go to: • 301G +24V Distribution RAP. • 301B 0V Distribution RAP. Install a new developer module, (45-55 ppm) PL 90.17 Item 2 or (65-90 ppm) PL 90.15 Item 2. Perform dC905 TC Sensor Calibration. Go to Flag 5. 0V is available at P/J93, pin 10. Y↓N→Go to the 301B 0V Distribution RAP. Enter dC131, 793-010, TC sensor control voltage. Record the displayed value (100 displayed equals 1 volt). Go to Flag 4. Check the voltage at P/J93, pin 9. The displayed value is within 0.2V of the voltage checked at P/J93, pin 9. Y↓N→Disconnect P/J93. Check the voltage at pin 9. The recorded value is within 0.2V of the voltage checked at P/J93, pin 9. Y↓N→Check the wiring, GP 7, between P/J93 and P/J6 on the IOT PWB. The wiring is good. Y↓N→Repair the wiring. Perform the TC increase adjustment. Perform the OF7 IOT PWB Diagnostics RAP. Perform the TC increase adjustment. Install a new developer assembly, (45-55 ppm) PL 90.17 Item 2 or (65-90 ppm) PL 90.15 Item 2. Perform dC905 TC Sensor Calibration. Enter dC330. Enter the code 042-010, main drive motor. Press start. Add the code 093- 040, toner dispense motor. Press Start. NOTE: The routine 93-040 times out after 5 seconds. The toner dispense motor runs. Y↓N→Go to Flag 2. Check MOT93-040. Refer to: • GP 10 How to Check a Motor. • P/J6, IOT PWB. • Go to 301G +24V Distribution RAP. • Go to 301B 0V Distribution RAP. If necessary, install a toner dispense module, (45-55 ppm) PL 90.17 Item 1 or (65-90 ppm) PL 90.15 Item 1. Check the toner dispense drive gears. The gears rotate. Y↓N→Install a new toner dispense module, (45-55 ppm) PL 90.17 Item 1 or (65-90 ppm) PL 90.15 Item 1. Add the code 093-310, low toner sensor. Energize the components in the following order: • 42-010, main drive motor. • 91-010, photoreceptor motor. • 93-040, toner dispense motor. When the toner dispense motor stops, the toner level sensor display value is low. Y↓N→Go to the 393-310-00, 393-390-00 Low Toner Sensor Failure RAP. Perform the TC increase adjustment. Check the wiring, GP 7, between P/J6 on the IOT PWB and P/J93 on the developer module. The wiring is good. Y↓N→Repair the wiring. Go to Flag 3. +24V is present at P/J93, pin 2. Y↓N→Disconnect P/J93. +24V is present at the harness end of P/J93, pin 2. Y↓N→Go to: • 301G +24V Distribution. • 301B 0V Distribution RAP. Install a new developer module, PL 90.15 Item 2. Perform dC905 TC Sensor Calibration. Go to Flag 5. 0V is available at P/J93 pin 10. Y↓N→Go to the 301B 0V Distribution RAP. Enter dC131, 793-010, TC sensor control voltage. Record the displayed value (100 displayed equals 1 volt). Go to Flag 4. Check the voltage at P/J93, pin 9. The displayed value is within 0.2V of the voltage checked at P/J93 pin 9. Y↓N→Disconnect P/J93. Check the voltage at pin 9. The displayed value is within 0.2V of the voltage checked at P/J93 pin 9. Y↓N→Check the wiring, GP 7, between P/J93 and P/J6 on the IOT PWB. The wiring is good. Y↓N→Repair the wiring. Perform the TC increase adjustment Perform the OF7 IOT PWB Diagnostics RAP. Perform the TC increase adjustment Install a new developer assembly, (45-55 ppm) PL 90.17 Item 2 or (65-90 ppm) PL 90.15 Item 2. Perform dC905 TC Sensor Calibration. Perform the TC reduction adjustment. If fault 93-360 is intermittent and causes the message Machine unavailable, perform the OF7 IOT PWB Diagnostics RAP then the TC reduction adjustment. TC reduction adjustment Perform the following: 1. Enter dC330, code 042-010, main drive motor; code 091-010, photoreceptor motor; 91- 066, developer bias. 2. Start the routine. The start will have to be pressed every 5 seconds to restart the developer bias routine. 3. Monitor the voltage output, Flag 1, at P/J6 pin 8 on the IOT PWB. NOTE: The toner concentration cannot be adjusted and maintained by making high area coverage prints. 4. Run the routine until the monitored voltage is greater than 0.9 volts. 5. Check the image quality. TC increase adjustment Perform the following: 1. Enter dC330, code 042-010, main drive motor; 93-040, toner dispense motor; 93-045, toner cartridge motor. 2. Start the routine. The start will have to be pressed every 5 seconds to restart the toner dispense motor and the toner cartridge routines. 3. Monitor the voltage output, Flag 1, at P/J6 pin 8 on the IOT PWB. 4. Run the routine until the monitored voltage is between 2.2 and 2.8 volts 5. Check the image quality.