Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 310-101-00A, 310-102-00A, 310-103-00A — Xerox WorkCentre 5865

Code: 310-101-00A, 310-102-00A, 310-103-00A

Description: Lead Edge Late to Fuser Exit Switch RAP (45-55 ppm) 310-101-00 The lead edge of the paper failed to actuate the fuser exit switch within the correct time after the registration clutch was energized for a simplex sheet. 310-102-00 The lead edge of the paper failed to actuate the fuser exit switch within the correct time after the registration clutch was energized for a duplex sheet side 1. 310-103-00 The lead edge of the paper failed to actuate the fuser exit switch within the correct time after the registration clutch was energized for a duplex sheet side 2.
Remedy: NOTE: The door interlock switch must be cheated when checking +24V components. Enter dC330 code 010-100 fuser exit switch, S10-100. Press Start. Manually actuate the switch with a piece of paper. The display changes. Y↓N→Go to Flag 1. Check S10-100. Refer to: • GP 13 How to Check a Switch. •. • P/J35, IOT PWB. • 301D +3.3V Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new fuser exit switch, PL 10.8 Item 11. If the fault remains, perform the OF7 IOT PWB Diagnostics RAP. W/TAG 001 machines only. Enter dC330 code 010-065 vacuum transport fan, MOT10-065.. Press Start, The fan runs. Y↓N→Go to Flag 2. Check MOT10-065. Refer to: • GP 10 How to Check a Motor. •. • P/J5, IOT PWB. • P/J17, LVPS. • Fuse, PL 1.10 Item 9, GP 7. • 301G +24V Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new short paper path assembly, PL 10.25 Item 1. If the fault remains, perform the OF7 IOT PWB Diagnostics RAP. Enter dC330 code 042-010 main drive motor. Press Start. Add code 82-070 registration clutch, CL08-070. Press Start. NOTE: The clutch will switch off after 5 seconds. The jam clearance knob 4c, PL 80.15 Item 10, rotates. Y↓N→Go to Flag 3. Check CL08-070. Refer to: • GP 12 How to Check a Solenoid or Clutch. • P/J5, IOT PWB. • P/J17, LVPS. • Fuse, PL 1.10 Item 9, GP 7. • 301G +24V Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new registration clutch, PL 80.15 Item 7. If the fault remains, perform the OF7 IOT PWB Diagnostics RAP. Enter dC330 code 082-150 registration sensor, Q82-150. Press Start. Manually actuate the sensor. The display changes. Y↓N→Go to Flag 4. Check Q82-150. Refer to: • GP 11 How to Check a Sensor. •. • P/J16, IOT PWB. • 301D +3.3V Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new registration sensor, PL 80.15 Item 3. If the fault remains, perform the OF7 IOT PWB Diagnostics RAP. Check the following components, refer to GP 7: • Registration roll, PL 80.15 Item 9. • Roll assembly on the short paper path assembly W/TAG 001, PL 10.25 Item 1. • Check the detack corotron and the connection to the HVPS. Refer to 391-060-00 HVPS Fault RAP • The drive gear on the fuser module, PL 10.8 Item 1. • The fuser drive gear on the main drives module, PL 40.17 Item 10. • Fuser web motor and the fuser web, refer to the 310A Fuser Web Motor RAP. • Check the drives plate on the registration clutch for damage and contamination. Refer to the replacement procedure. • If the fault remains, perform the 301L LVPS Checkout RAP.

← Xem tất cả mã lỗi Xerox WorkCentre 5865

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie