Code: 03010000-2F33
Description: Adjustment error. Auto head alignment selected from the user menu could not be carried out because the alignment patter read result was NG. Auto LF adjustment selected from the user menu or in the service mode could not be carried out because the adjustment patter read result was NG. Decentering correction selected in the service mode cannot be carried out because the correction pattern read result was NG. Auto LF adjustment selected from the user menu or in the service mode could not be carried out because the head check patter read result was NG.
Causes: Operation method, printhead, multi sensor, carriage PCB, or main controller PCB
Remedy: 1. Check whether the media type selected on the operation panel is the same as the type of the media used to print the adjustment pattern. If they are different, retry adjustment using the media of the type selected on the operation panel. 2. If ink bleeds greatly, change the media. 3. Carry out head cleaning, and retry adjustment. If the adjustment result is poor, replace the printhead. 4. Replace the multi sensor, and then retry adjustment. 5. Cable continuity check If continuity of the cable between the multi sensor and the main controller PCB is abnormal, replace the cable. 6. Replace the carriage PCB. 7. Cable continuity check If continuity of the cable between the carriage PCB and the main controller PCB is abnormal, replace the cable. 8. Replace the main controller PCB.